FCP and SES Commands
8946121402 3-15
Send DiagnosticA SES Application Client can use a Send Diagnostic command to configure/diagnose a
logical unit. After the command completion, the SES Application Client sends a Receive
Diagnostic Results command. See Table 3-22. The FCP_CDB format is shown in
Table3-26.
A Page Format (PF) bit of 1 specifies that the Send Diagnostic parameters conform to the
page structure as specified in SCSI-3 Primary Command (SPC), Revision 11a, X3T10/995D,
working draft. A value of 0 specifies that all parameters are vendor specific. At present, the
SESD only supports the vendor-specific page structures as defined in the “Switch Diagnostics
Pages” section.
The selfTest,DevOfL and UnitOfL bits are ignored by the SESD at present.
The ParameterList Length field specifies the length in bytes of the parameter list that shall be
transferred from the SES Application client to the SESD.
Test Unit ReadyAn SES Application Client sends a Test Unit Ready command to check if the logical unit
is ready. The FCP_CDB format is shown inTable 3-27.
The SESD returns the status of GOOD and CHECK CONDITION and a sense key of NO SENSE
and an additional sense code of NO ADDITIONAL SENSE INFORMATION.
Table 3-26 Send Diagnostic Command Format
Byte/Bit 7 6 5 4 3 2 1 0
0 Operation Code = 1Dh
1 Reserved PF Reserved selfTest DevOfL UnitOfL
2 Reserved
3 .. 4 Parameter list length
5 Control = 0
Table 3-27 Test Unit Ready Command Format
Byte/Bit 7 6 5 4 3 2 1 0
0 Operation Code = 00h
1 .. 4 Reser ved
5 Control = 0