Installer / Supplier details

SITE REQUIREMENTS / INSTALLATION

To assist us in any Guarantee claim please complete the following information: -

Stovax dealer the appliance was purchased from

Name:...........................................................................................................................................................................................

Address:.........................................................................................................................................................................................

......................................................................................................................................................................................................

Telephone number:.......................................................................................................................................................................

Date installed:................................................................................................................................................................................

Model description:.........................................................................................................................................................................

Installation Engineer

Name:...........................................................................................................................................................................................

Address:.........................................................................................................................................................................................

......................................................................................................................................................................................................

Telephone number:.......................................................................................................................................................................

General

Before installation of this product please read these instructions fully.

It is very important to also understand the requirements of the UK Building Regulations (England and Wales – Document J / Scotland - Part F), along with any local regulations, and working practices that may apply. Should any conflict occur between these instructions and these regulations then the regulations shall apply.

All electrical connections should meet the requirements of UK Building Regulations (England and Wales – Document P / Scotland - Part N).

Your local Building Control Office would be happy to advise should questions arise, regarding the requirements of the regulations.

The fireplace should be fitted by a HETAS (GB only) registered installer, or approved by your local building control officer. Your Stovax dealer should be able to arrange this service for you.

Any gas appliance installation completed in conjunction with the fireplace must be completed by a CORGI registered gas engineer, in accordance with the manufactures installation instructions. Your Stovax dealer should be able to arrange this service for you.

Your building insurance company may also require you to inform them that you have installed a new heating appliance, so check with your insurers that your cover is still valid after installing the fireplace.

When completing the installation and building works you should comply with your responsibilities under the Health and Safety at Work Acts, and any new regulations, which may be introduced during the lifetime of these instructions.

A faulty installation could cause danger to the inhabitants and structure of the building.

Hearth

The constructional and superimposed hearth must meet the requirements of the Building Regulations for the fire and surround to be fitted.

Flue

The flue system should meet the requirements of the Building Regulations for the fire to be fitted and the fuel to be used.

The flue exit from the building should be positioned to comply with the requirements of the Building Regulations.

Any existing flue should be confirmed as suitable for the new intended use, as defined in the Building Regulations.

Any existing flue or chimney system must be inspected and swept by a NACS registered (UK only) chimney sweep, to confirm that the system is structurally sound and free from any obstructions.

Suitable access should be provided to enable the collection and removal of debris.

Provision should be made to sweep and inspect the flue when the appliance is installed.

No other heating appliances should be connected to, or share, the same flue or chimney system.

Check the flue draught. This should be done with all windows and doors closed and any extraction fans in this or adjoining rooms running at maximum speed.

Note: A guide containing general information on Chimneys and

Flues is obtainable from: -

The British Flue & Chimney Manufacturers’ Association,

FETA

2 Waltham Court, Milley Lane,

Hare Hatch

 

Reading,

 

Bucks ,

 

RG10 9TH

 

Tel : - 01189 403416

e-mail :- info@feta.co.uk

Where a hearth, fireplace, flue or chimney is provided or extended (including cases where a flue is provided as part of refurbishment work), information essential to the correct appliance and use of these should be permanently posted in the building, to meet Requirement J4 of the Building Regulations (England and Wales), F3.12 (Scotland).

Fireplace opening

As all fireplaces are different it is not possible to give full details of the construction of the fireplace opening. But this should be constructed using ‘best practice’ construction methods using suitable non-combustible materials.

Additional ventilation

If the fireplace is to be used with Solid fuel, Gas, or Oil products additional ventilation will be required. This should meet the requirements of the Building Regulations for the fire to be fitted and the fuel to be used. This should be provided using a permanently open air vent, which is positioned so that it is not liable to be blocked both inside and outside the building.

If any of these checks reveal problems do not proceed with the fitting of the fireplace until they have been rectified.

Dimensions

Fitting optional insert panel (8904)

The insert panel is fitted to the back of the main front panel using the 4 fixing screws supplied. This will then allow fitting of both Stovax and Gazco 16” products.

2

3

Page 2
Image 2
Stovax 8902, 8903, 8901, 8904 installation instructions Site Requirements / Installation

8904, 8902, 8901, 8903 specifications

The Stovax range of gas stoves, including the 8904, 8903, 8901, and 8902 models, represents the pinnacle of modern heating technology combined with aesthetic excellence. These stoves are designed to provide both warmth and ambiance while ensuring maximum efficiency and minimal environmental impact.

One of the main features of the Stovax 8900 series is their high efficiency rating. All models are engineered to produce a significant amount of heat while consuming less gas, making them economically advantageous for consumers looking to lower their energy bills. The stoves achieve high combustion efficiency, meaning more heat is generated from the fuel consumed.

The aesthetic versatility of the Stovax stoves is another distinctive characteristic. The 8904, 8903, 8902, and 8901 models come in various finishes, including classic black, contemporary steel, and more traditional styles, allowing homeowners to select a design that complements their interior decor. Furthermore, these stoves have a range of options for door finishes and handle styles, adding a personal touch to the installation.

In addition to their appearance, each stove in the 8900 series incorporates advanced technologies that enhance user experience and safety. The intelligent air control system allows for effortless regulation of the flame height and temperature, providing both convenience and effectiveness, whether it's a cozy evening or a chilly winter day. The unique burner system ensures even heat distribution throughout the room, enhancing comfort levels.

Safety is paramount in Stovax's design philosophy, and the 8900 series does not disappoint. Each model is equipped with robust safety features, such as a flame supervision device and an automatic shut-off option, providing peace of mind for users. The stoves also have a ceramic burner that ensures a cleaner burn, reducing emissions and contributing to a healthier environment.

The compatibility of these stoves with various flue systems offers flexibility in installation. Whether vented through a wall or into a traditional chimney, the Stovax 8900 series can be adapted to fit a range of home configurations, making them an ideal choice for many.

In conclusion, the Stovax 8904, 8903, 8901, and 8902 gas stoves combine energy efficiency, aesthetic appeal, and advanced technologies, making them excellent choices for anyone looking to enhance their home's heating while contributing to a sustainable future. With their safety features, customizable appearances, and superior performance, these stoves are a reliable and stylish heating solution for modern living.