PRE-INSTALLATION CHECKS

PRE-INSTALLATION CHECKS

1. VENTILATION

Model

 

 

 

 

 

 

 

 

 

 

16" Riva Open

22" Riva Open

24" Riva Open

26" Riva Open

28" Riva Open

 

 

 

 

 

 

 

 

 

Without liner system (round)

mm

200

200

200

200

200

 

 

 

 

 

 

 

 

minimum dimension (diameter.)

inch

8

8

8

8

8

 

 

 

 

 

 

 

 

 

 

Flue/Chimney Size

Without liner system (square)

mm

185

185

185

185

185

 

 

 

 

 

 

minimum dimension

inch

7 1/4

7 1/4

7 1/4

7 1/4

7 1/4

 

 

 

 

 

 

 

 

 

 

 

 

Liner or factory made system

mm

200

200

200

200

200

 

(diameter.)

 

 

 

 

 

 

 

inch

8

8

8

8

8

 

installed in accordance with manufacturers instructions

 

 

 

 

 

 

 

 

 

Do not connect to systems containing large voids or over 9" (230mm) square/round

 

 

 

 

 

 

 

 

 

 

Flue/Chimney

All Products

m

4.5

4.5

4.5

4.5

4.5

 

 

 

 

 

 

minimum height*

feet

15

15

15

15

15

 

 

 

 

 

 

 

 

 

 

 

* When measured from the top of the appliance to the top of the flue, with no horizontal sections

and a maximum of 4 bends with angles of less than 45°

1.1This appliance requires ventilation to supply combustion air. Any room containing the appliance must have a permanent air vent opening with a total free area of at least 550mm2 per kW of appliance rated output above 5kW.

1.2Increase air supply provisions where a room contains multiple appliances.

1.3If vents open into adjoining rooms or spaces there must be an air vent of at least the same size direct to the outside.

1.4Permanent air vents should be non-adjustable and positioned where they are unlikely to become blocked.

1.5Site the vents where cold draught is unlikely to cause discomfort. This can be avoided by placing vents near ceilings or close to the appliance, see Diagram opposite.