Stovax PM219 manual Additional Ventilation, Pre-Installationchecks, Riva Open

Models: PM219

1 32
Download 32 pages 36.29 Kb
Page 18
Image 18
2. ADDITIONAL VENTILATION

PRE-INSTALLATION CHECKS

2. ADDITIONAL VENTILATION

2.1Open appliances require additional ventilation to comply with the requirements of the Building Regulations. This should be provided using a permanently open air vent, of the size listed, which is positioned so that it is not liable to be blocked both inside and outside the building.

2.2Extractor fans or cooker hoods should not be placed in the same room or space as the appliance.

2.3If any of these checks reveal problems do not proceed with the fitting of the appliance until they have been rectified.

Model

 

 

 

 

 

 

 

 

16" Riva Open

22" Riva Open

24" Riva Open

26" Riva Open

28" Riva Open

 

 

 

 

 

 

 

 

mm2

14400

16538

19215

21735

21735

Additional Ventilation

cm2

144

165

192

217

217

 

in2

22.32

25.63

29.78

33.69

33.69

 

 

 

 

 

 

 

 

 

18

Page 18
Image 18
Stovax PM219 manual Additional Ventilation, Pre-Installationchecks, Riva Open