INSTALLATION INSTRUCTIONS
TECHNICAL SPECIFICATION
COVERING THE FOLLOWING MODELS:
MARLBOROUGH – 8610LUC – P8610LUC
STOCKTON – 8617LUC – P8617LUC
Model | Gas | Gas | Working | NOX | Aeration | Injector | Gas Rate | Input kW (Gross) | Country | |
|
|
|
|
|
|
| m3/h |
|
|
|
| CAT. | Type | Pressure | Class |
|
| High | Low |
| |
Marlborough 8610LUC | I2H | Natural | 20 mbar | 3 | Ø 14.5 | 375 | 0.623 | 6.6 | 3.6 | GB, IE |
|
| (G20) |
|
|
|
|
| Gross | Gross |
|
Marlborough P8610LUC | I3P | Propane | 37 mbar | 3 | Ø 11.5 x 2 | 165 | 0.232 | 6.4 | 3.6 | GB, IE |
|
| (G31) |
|
|
|
|
| Gross | Gross |
|
Stockton – 8617LUC | I2H | Natural | 20mbar | 3 | Ø 14.5 | 375 | 0.623 | 6.6 | 3.6 | GB, IE |
|
| (G20) |
|
|
|
|
| Gross | Gross |
|
Stockton – P8617LUC | I3P | Propane | 37mbar | 3 | Ø 11.5 x 2 | 165 | 0.232 | 6.4 | 3.6 | GB, IE |
|
| (G31) |
|
|
|
|
| Gross | Gross |
|
Efficiency Class II
Flue Outlet Size 127mm (5”) Ø
Gas Inlet Connection Size 8mm Ø
Minimum Flue Specification T260 / N2 / 0 / D / 1
Maximum Flue Temperature 180°C
Packing Checklist
Qty Description
1 Stove
1Flue Blanking plate
1Coal Retainer
1Log set (5 logs)*
2Ash Panels* (2 sections)*
1Fixing Kit Containing 1 Instruction Manual
1 Wood Screw
1 Rawplug
1 Box spanner *Packed in appliance
1
AR1623
8