Stow G-4.5R manual Operation and Safety Decals S/N 5498030 and below, Machine Safety Decals

Models: G-4.5R

1 76
Download 76 pages 48 Kb
Page 14
Image 14

OPERATION AND SAFETY DECALS (S/N 5498030 AND BELOW)

Machine Safety Decals

The G-4.5R portable generator is equipped with a number of safety decals (Figures 2A and 2B). These decals are provided for operator safety and maintenance information.The illustration below shows these decals as they appear on the machine.Should any of these decals become unreadable, replacements can be obtained from your dealer.

S-4984

DANGEROUS

GAS

WARNING

Only operate machine in well ventilated areas.

DO NOT inhale exhaust gases.

Only qualified personnel should install, use or service this equipment.

P/N A3562000003

FUEL COCK

 

 

 

 

 

 

 

 

ON

 

MODEL

 

 

 

 

 

 

SERIAL NO.

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTACT

 

 

 

 

 

 

S-3704

STOW PARTS DEPT.

 

 

 

 

 

P/N 8700611804

 

DANGER

 

Do not touch output terminals or

 

internal wiring while unit is operating.

S-4985

Turn off power before servicing.

DANGEROUS

Only qualified personnel should

install, use or service this

GAS

equipment.

P/N 8700611904

CAUTION

P/N 1980680004

S-1123

P/N 0800628504

CAUTION!

READ OWNER’S SERVICE MANUAL BEFORE OPERATING OR SERVICING THIS MACHINE.

ALWAYS KEEP UNAUTHORIZED, INEXPERIENCED, UNTRAINED PEOPLE AWAY FROM THIS MACHINE.

MAKE SURE ALL SAFETY DEVICES ARE OPERNATIONAL BEFORE THIS MACHINE IS STARTED. MAKE SURE ENGINE IS TURNED OFF AND SPARK PLUG WIRE DISCONNECTED BEFORE SERVICING THE MACHINE OR COMING IN CONTACT WITH ANY MOVING PART. IF EQUIPMENT IS POWERED BY AN ELECTRIC MOTOR, DISCONNECT ELECTRICAL PLUG.

NEVER LEAVE MACHINE UNATTENDED WHEN OPERATING ALWAYS STOP ENGINE AND ALLOW ENGINE TO COOL BEFORE ADDING FUEL OR OIL.

DCS01

OPERATE AT

3600 RPM ONLY

(FULL THROTTLE)

DAMAGE MAY RESULT IF

OPERATED AT LOWER SPEEDS

P/N 7900636004

WARNING!

Before connecting this generator to any building’s electrical system, a licensed electrician must install an isolation (transfer) switch.

Serious injury or death may result without this transfer switch.

P/N 0820610404

P/N 0820610304

OPERATING INSTRUCTIONS

1.Before starting check the oil and fuel level.

2.Switch the circuit breaker to the “OFF” position.

3.Open the fuel valve.

4.Pull the choke knob.

5.Turn the operation switch to the "RUN" position and push.

6.Pull the recoil starter.

7.After the engine starts, gradually push in the choke valve.

8.Run the generator for 3-5 minutes without load.

9.Check for any abnormal noise or smell.

10.Switch the circuit breaker to the “ON” position.

11.When stopping, remove the load and allow it to continue to run for 2-3 minutes before stopping engine.

12.Turn the operation switch to the "STOP" position.

13.After the engine completely stops. Close the fuel valve.

S-4607

P/N 7900638204

RUN

STOP

IDLE

G-4.5RCONTROL OPERATION SWITCH

 

 

120V

 

 

 

240/120V

AC VOLTMETER

AC CIRCUIT

FULL POWER

 

 

BREAKER

SWITCH

 

P/N A3512100502

OIL

ALARM

240V

GFCI120V

GROUND

Figure 2A. Operation and Safety Decals (S/N 5498030 and Below)

PAGE 14 — STOW G-4.5R A.C. GENERATOR— OPERATION & PARTS MANUAL — REV. #3 (03/13/06)

Page 14
Image 14
Stow G-4.5R manual Operation and Safety Decals S/N 5498030 and below, Machine Safety Decals

G-4.5R specifications

The Stow G-4.5R is an exceptional piece of rugged engineering designed for professionals who require efficiency and reliability in demanding environments. This cutting-edge equipment stands out for its unique combination of robust features and innovative technologies.

At the heart of the G-4.5R is its powerful engine, designed to facilitate high-performance operations. The machine is equipped with a fuel-efficient powertrain that not only maximizes output but also minimizes consumption. This feature is crucial for users who need to operate over extended periods without frequent refueling, making the G-4.5R highly suitable for long-term projects.

The G-4.5R boasts an advanced hydraulic system that enhances its lifting capabilities. With optimized hydraulic mechanics, the machine can handle heavier loads with improved precision and speed. This ensures that users can perform tasks more efficiently, reducing downtime and increasing productivity. Furthermore, the hydraulic system is complemented by a robust frame, designed to withstand rigorous field conditions while providing stability during operation.

Another notable aspect of the Stow G-4.5R is its user-centric design. The operational interface is intuitively laid out, allowing users to easily navigate controls and features without extensive training. The ergonomic design of the operating cabin further enhances comfort, reducing fatigue during long working hours. Noise reduction technologies have also been integrated into the design, making the working environment more pleasant.

In terms of technology, the G-4.5R features real-time monitoring systems that provide crucial operational data. These systems allow users to track fuel levels, hydraulic pressures, and performance metrics at a glance. Such capabilities not only promote efficient resource management but also facilitate preventive maintenance, helping to prolong the machine’s lifespan.

Safety is paramount in the design of the G-4.5R, with multiple safety mechanisms in place. These include automatic shutdown features in case of system overloads, reinforced caging to protect operators, and enhanced visibility systems that ensure a clear line of sight during operation.

In summary, the Stow G-4.5R is a versatile, powerful, and user-friendly machine specifically designed for challenging work environments. With its combination of advanced technologies, ergonomic design, and safety features, the G-4.5R stands out as a top choice for professionals aiming for efficiency and reliability in their operations.