STOWT-30H — TROUBLESHOOTING (ENGINE/PUMP)

TABLE 7. ENGINE TROUBLESHOOTING (Continued)

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

 

 

Operation not satisfactory

 

 

 

 

 

 

Governor adjustment improper?

Adjust governor to correct lever.

 

 

 

 

Governor spring defective?

Clean or replace ignition.

Rotational speed fluctuates.

 

 

Fuel flow erratic?

Check fuel line.

 

 

 

 

 

Air taken in through suction

Check suction line.

 

line?

 

 

 

 

Recoil starter not working

Dust in rotating part?

Clean recoil starter assembly.

 

 

properly.

Spring spring failure?

Replace sprial spring.

 

 

 

 

TABLE 8. PUMP TROUBLESHOOTING

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

 

 

 

Not enough priming water in the housing?

Add water.

 

 

 

 

Engine speed too low?

Increase throttle.

 

 

 

 

Strainner plugged?

Clean strainer.

 

 

 

 

Suction hose damaged?

Replace or repair hose, and clamps

 

 

 

 

Air leak at suction port?

Check that fittings are tight and properly sealed.

Pump does not take on water.

 

 

Pump is located too high above water line?

Move pump closer to water.

 

 

 

 

 

Debris collecting in pump housing?

Clean pump housing.

 

 

 

 

Too much distance between impeller and volute.

Adjust clearance by adding shims or replace impeller.

 

Min. .006" - Max. .020"

 

 

 

 

 

 

Water leaking out weep hole between pump and

Check condition of mechanical seal and gaskets,

 

engine?

between pump end and engine housing.

 

 

 

 

Engine speed too low?

Increase throttle speed.

 

 

 

Pump takes in water, little or no

Suction strainer partially plugged?

Clean strainer.

discharge.

 

 

Impeller/Volute worn?

Adjust clearance by adding shims or replace

 

 

 

impeller/volute

 

 

 

 

Fittings/clamps are not sealed properly?

Tighten, replace or add clamp. (Keep extra seals on

Suction hose leaks at inlet.

pump)

 

 

 

 

Hose diameter is too large?

Use smaller diameter hose or replace hose.

 

 

 

Discharge does not stay on

Pressure too high?

Check pressure, add additional clamp.

 

 

coupling.

Hose kinked or end blocked?

Check hose.

 

 

 

 

 

Impeller jammed or blocked?

Open pump cover and clean dirt and debris from

 

 

inside housing.

Impeller does not turn: pump is

 

 

 

Adjust clearance by removing shim from behind

hard to start.

Impeller and volute binding?

impeller.

 

 

 

 

 

 

Defective engine?

See Engine Owner's Manual.

 

 

 

STOW T-30H TRASH PUMP — PARTS MANUAL— REV. 0 (05/30/03) — PAGE 27

Page 27
Image 27
Stow manual STOWT-30H Troubleshooting ENGINE/PUMP

T-30H specifications

The Stow T-30H is an advanced stadium and event venue turbine heater that combines efficiency, performance, and cutting-edge technology, making it a preferred choice for a range of applications. Designed specifically to provide optimal heating solutions in large spaces, the T-30H stands out due to its unique features and functionalities.

One of the primary features of the Stow T-30H is its robust heating capacity. With a heating output that can reach up to 30 kW, the unit is capable of efficiently warming areas of significant size. This makes it particularly suitable for indoor sporting events, exhibition halls, and outdoor venues during the colder months. The heater is also engineered to quickly and effectively raise the temperature in a controlled manner, ensuring that users remain comfortable in any setting.

The T-30H incorporates innovative technology designed to maximize its efficiency. It utilizes an advanced combustion system that not only improves fuel consumption but also minimizes emissions. This eco-friendly approach aligns with modern sustainability goals, making the heater an attractive choice for organizations aiming to reduce their carbon footprint.

The ease of operation is another noteworthy characteristic. The Stow T-30H features a user-friendly control panel that allows operators to set and adjust the heating levels conveniently. Additionally, it includes built-in safety mechanisms, such as overheat protection and flame failure detection, ensuring safe operation at all times.

Portability is key in the design of the T-30H. The unit is equipped with durable wheels and a compact profile, allowing for easy transportation and set-up across different locations. This makes it an ideal solution for event organizers who need a heating solution that is both efficient and flexible.

Furthermore, the Stow T-30H is compatible with various fuel sources, offering versatility for users. With options for propane, natural gas, and diesel, it can cater to diverse operational needs and preferences.

In summary, the Stow T-30H delivers powerful heating capabilities combined with modern technology and user-friendly operation. Its focus on efficiency, safety, and portability makes it an excellent choice for stadium and event venue heating needs, ensuring comfort for participants and audiences alike. With this remarkable heater, organizations can enhance the experience of their events, no matter the season.