DANGER:

Failure to follow instructions in this manual may lead to serious injury or even death! This equipment is to be operated by trained and qualified personnel only! This equipment is for industrial use only.

The following safety guidelines should always be used when operating the trash pump:

GENERAL SAFETY

DO NOT operate or service this equipment before readingthisentiremanual.

This equipment should not be operated by persons under 18 years of age.

NEVER operate this equipment without proper protective clothing, shatterproof glasses, steel- toed boots and other protective devices required by the job.

NEVER operate this equipment when not feeling well due to fatigue, illness or taking medicine.

NEVER operate this equipment under the influence or drugs or alcohol.

Whenever necessary, replace nameplate, operation and safety decals when they become difficult read.

ALWAYS check the machine for loosened threads or bolts before starting.

ALWAYS wear proper respiratory (mask) hearing and eye protection equipment when operating the pump.

RULES FOR SAFE OPERATION

NEVERtouchthehotexhaustmanifold, muffler or cylinder.Allow these parts to cool before servicing engine or pump.

HighTemperatures – Allow the engine to cool before adding fuel or performing service and maintenance functions. Contact with hot components can cause serious burns.

The engine of this pump requires an adequate free flow of cooling air. NEVER! operate the pump in any enclosed or narrow area where free flow of the air is restricted. If the air

flow is restricted it will cause serious damage to the pump or engine and may cause injury to people and property. Remember the pump's engine gives off DEADLY gases.

ALWAYS refuel in a well-ventilated area, away from sparks and open flames.

ALWAYS use extreme caution when working with flammable liquids. When refueling, stop the engine and allow it to cool. DO NOT smoke around or near the machine. Fire or explosion could result from fuel vapors, or if fuel is spilled on a hot engine.

NEVER operate the pump in an explosive atmosphere or near combustible materials. An explosion or fire could result causing severe bodily harm or even death.

Topping-off to filler port is dangerous, as it tends to spill fuel.

Refer to the Engine Owner's Manual for engine technical questions or information.

NEVER use accessories or attachments, which are not recommended by Multiquip for this equipment. Damage to the equipment and/or injury to user may result.

Manufacturer does not assume responsibility for any accident due to equipment modifications.

PAGE 8 — STOW T-30H TRASH PUMP — PARTS MANUAL — REV. #0 (05/30/03)

Page 8
Image 8
Stow T-30H manual Rules for Safe Operation, General Safety

T-30H specifications

The Stow T-30H is an advanced stadium and event venue turbine heater that combines efficiency, performance, and cutting-edge technology, making it a preferred choice for a range of applications. Designed specifically to provide optimal heating solutions in large spaces, the T-30H stands out due to its unique features and functionalities.

One of the primary features of the Stow T-30H is its robust heating capacity. With a heating output that can reach up to 30 kW, the unit is capable of efficiently warming areas of significant size. This makes it particularly suitable for indoor sporting events, exhibition halls, and outdoor venues during the colder months. The heater is also engineered to quickly and effectively raise the temperature in a controlled manner, ensuring that users remain comfortable in any setting.

The T-30H incorporates innovative technology designed to maximize its efficiency. It utilizes an advanced combustion system that not only improves fuel consumption but also minimizes emissions. This eco-friendly approach aligns with modern sustainability goals, making the heater an attractive choice for organizations aiming to reduce their carbon footprint.

The ease of operation is another noteworthy characteristic. The Stow T-30H features a user-friendly control panel that allows operators to set and adjust the heating levels conveniently. Additionally, it includes built-in safety mechanisms, such as overheat protection and flame failure detection, ensuring safe operation at all times.

Portability is key in the design of the T-30H. The unit is equipped with durable wheels and a compact profile, allowing for easy transportation and set-up across different locations. This makes it an ideal solution for event organizers who need a heating solution that is both efficient and flexible.

Furthermore, the Stow T-30H is compatible with various fuel sources, offering versatility for users. With options for propane, natural gas, and diesel, it can cater to diverse operational needs and preferences.

In summary, the Stow T-30H delivers powerful heating capabilities combined with modern technology and user-friendly operation. Its focus on efficiency, safety, and portability makes it an excellent choice for stadium and event venue heating needs, ensuring comfort for participants and audiences alike. With this remarkable heater, organizations can enhance the experience of their events, no matter the season.