REMOVE THE PLASTIC COVER from the xenon bulb. Store the protective cover and the original bulb packing in a secure location. The spare anode adapter (65199) is for use with an OSRAM 700 watt bulb (XBO700W/HS OFR) should such a bulb be used as a replacement.

SECURE THE LAMPHOUSE COVER with the (4) tamperproof screws using the special screwdriver provided. The cover must be securely in position to actuate the interlock switch and permit lamp ignition.

IT IS RECOMMENDED to establish a routine for periodically checking all electrical connec- tions for tightness, particularly those at the bulb. A loose connection in the DC circuit will cause failure of the contacts and leads, and may damage the bulb.