STUDER INNOTECSI

STUDER INNOTECSI

Technical data

Model SI

612

812

 

1212

1624

2324

3324

3548

 

624

824

1224

 

2348

 

 

 

648

 

1248

 

 

 

 

Input voltage (Unom) [V]

12/24/48

12/24

12/24/48

24

24V/48

24

48

 

 

 

 

 

 

 

 

 

Nominal power [W]

600

800

1200

1600

2300

3300

3500

 

 

 

 

 

 

 

 

 

« Standby » current [mA]

25/21/10

25/21

25/21/12

21

25/17

25

30

Power « ON » no load [W]

2.6

2.8

4.8

5.8

9

13

17

 

 

 

 

 

 

 

 

 

Power « ON » no load [W]

--------

-------

< 0.5

< 0.5

< 0.6

< 0.7

< 0.8

TWINPOWER system

 

 

 

 

 

 

 

 

Maximum efficiency [%]

91

92

93 - 95

93 - 95

95

95

95

 

 

 

 

 

 

 

 

 

Length L x 124 (H) x 215 (W) [mm]

276

276

391

391

591

636

791

 

 

 

 

 

 

 

 

 

Weight [kg]

6.9

10.4

13.2

15.2

27

30

38

 

 

 

 

 

 

 

 

 

Input voltage

Dynamic correction of Umin.

Output voltage

Distortion

Dynamic behaviour

Frequency

Charge detection (standby)

Maximum power 15 min

Maximum power 3 min

Peak power 5s

Asymmetric load

Cos ϕ

Protections

IP protection index

Forced ventilation

Overheating protection

Required battery capacity

Acoustic level

EEC conformity

Min. - Max.: < Unom x 0.95 to Unom x 1.33 - 10% at Pnom

True sine 230 Vac ±3% < 2% (at Pnom)

From 0% to 100% load change. Normalization: 0.5 ms

50Hz ±0.01% (Crystal control) Adjustable: 0.3 20 W

1.3 – 1.6 x Pnom / 25°C

1.6 – 2 x Pnom / 25°C

3.5 x Pnom

Up to 2 x Pnom 0.1 – 1

Overload/Overheat/Short-circuit/Reverse polarity by internal fuse IP 20 complies with DIN 40050/IP 23 with top cover

From 45°C ± 3°C 75°C ± 3°C

> 5x Pnom/Unom (recommended value)

Without ventilation: < 10 dB

With ventilation:< 35 dB

EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022, EN 61000-3-2, Dir. 89/336/EEC, LVD 73/23/EEC

Options

3-phased system (per unit) from SI 1200

SIxxxxPE

TwinPower system from SI 1200

SIxxxxTP

Top cover IP 23

C-IP23

 

SIxxxxA

Potential free alarm contact (60V/0.5A) for all models

Solar charge controller 16A/12-24V for SI 600 and SI 800

SIxxxS

Industrial casing in 19’’ rack – 3U x 400 mm from SI 1200

SIxxxxIND

Other specifications on request (Ex: 115V/60Hz).

These data are for information only and may change without notice.

SI in industrial casing 19’’ rack

User manual

SI V3.0 E

10

Page 10
Image 10