14 Table of standard configurations
No. of
config. Denomination / description Fact.
valu
e
Mod.
value G1
1
kVA
G2
2
kVA
G3
3
kVA
1107 Maximum current of the AC source A 30 3.5 7 12
1108 Undervoltage of the empty battery V/cell 1.9
1109 Sub-voltage of the charged battery V/cell 1.75
1110 Restart voltage of the inverter after undervoltage of the
battery V/cell 2
1111 Automatic startup at energisation No
1111 Automatic startup at energisation of the battery No
1112 Inverter frequency Hz 50
1121 Maximum DC voltage for stopping the Xtender V/cell 2.84
1126 Source backup (smart boost) permitted No
1133 Number of restarts after stoppage 2
1138 Battery charge current A 80
1139 Battery voltage correction according to the temperature mV/°
C/cell -5
1140 Battery maintenance voltage V/cell 2.27
1156 Battery absorption voltage V/cell 2.4
1157 Duration of absorption h 2
1159 Current at end of absorption Adc 2
1187 Sensitivity of the charge detection 3
1190 Duration of undervoltage of battery before disconnection min. 3
1191 Dynamic compensation for undervoltage Yes
1198 Time elapsing before transfer relay opens sec. 0 5
1199 ACin voltage causing the opening of the transfer relay Vac 180
1200 Immediate open critical threshold for the transfer Vac 50
1300 Number of overloads permitted before definite stoppage -- 2
1303 Number of battery overvoltages accepted before definite
stoppage
-- 3
1304 Number of battery undervoltages permitted before definite
stoppage
-- 3
1309 Minimum ACin voltage to authorise charging Vac 185
1403 Period for counting battery overvoltages sec. 30
1404 Period for counting battery undervoltages sec. 30
1432 Maximum ACin voltage to switch to inverter mode Vac 265
1436 Authorise exceeding of the input current limit without
interrupting the transfer
No
1470 ACin voltage hysteresis for closing the transfer relay Vac 20
1485 Automatic earth-neutral connection in inverter mode No
1488 Serious undervoltage of the battery V/cell 1.5
1505 Delta of higher frequency accepted Hz 15
1506 Delta of lower frequency accepted Hz 5
1286 Output voltage Vac 227