INTEGRATED REFRIGERATION
Electrical
The electrical supply must be located within the shaded area shown in the illustration and chart below. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
The electrical outlet must be positioned with the grounding prong to the right of the thinner blades.
Installation must comply with all applicable electrical codes.
ELECTRICAL REQUIREMENTS |
|
Electrical Supply | 115 VAC, 60 Hz |
Service | 15 amp |
Receptacle | |
ELECTRICAL SUPPLY LOCATION |
|
MODEL | A |
27" Model | 13" (330) |
36" Model | 171/2" (445) |
LEFT SIDE |
OF OPENING |
Plumbing
The water supply line should be located within the shaded area shown in the illustrations below. The water supply line should be connected to the house supply with an easily accessible
A reverse osmosis system can be used provided there is constant water pressure of
Installation must comply with all applicable plumbing codes.
PLUMBING REQUIREMENTS |
|
Water Supply | 1/4" OD copper, braided |
| stainless steel or PEX tubing |
Pressure | |
Excess Line for Connection | 27" (686) |
WATER SUPPLY LOCATION |
|
MODEL | A |
27" Model | 9" (229) |
36" Model | 131/2" (343) |
|
|
| 21/2" |
|
|
| A |
|
|
|
| |||
|
|
|
|
|
|
| ||||||||
|
|
| (64) |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 41/2" |
| |
|
|
|
|
|
|
|
|
|
|
|
| (114) |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| FLOOR |
|
| ||||||
|
|
|
|
|
|
|
| |||||||
|
|
|
|
| ||||||||||
|
|
| 1/4" (6) |
|
|
|
|
|
|
|
|
|
|
Electrical supply location.
RIGHT SIDE | |
OF OPENING | |
A | 21/2" |
| (64) |
3" (76) |
|
FLOOR | 3/4" (19) |
|
Water supply location (rear).
| 11/2" (38) |
BACK WALL |
|
6" |
|
(152) |
|
A | 21/2" |
| (64) |
RIGHT SIDE | |
OF OPENING |
Water supply location (bottom).
subzero.com/specs 7