INTEGRATED REFRIGERATION
Custom Panels
For integrated models, custom door panels and handle hardware must be provided. Refer to the panel requirements chart and integrated panel dimensions.
INTEGRATED PANEL DIMENSIONS
The thickness of the custom panel can vary. A minimum 5/8" (16) thick panel is required, but the thickness can be increased provided it does not exceed the weight limit. The depth of each integrated model is 24" (610). Allow for panel thickness when planning the finished opening depth. Refer to the
CAUTION
When using a 3/4" (19) or thicker panel with a reveal less than 1/4" (6), panel may cause damage to the unit when door is opened to 105°. Use the
CAUTION
W
Column
767/8"
(1953)
W
Tall
453/8"
(1153)
139/16"
(345)
1611/16"
(424)
W
Drawer
As reveals between cabinetry and the unit decrease, severe finger pinching can occur while door is closing.
Finish all sides of custom panels. They will be visible when the door/drawer is open.
PANEL REQUIREMENTS
PANEL WEIGHT | MAX |
Column | 65 lb (29 kg) |
27" Tall (door) | 40 lb (18 kg) |
36" Tall (door) | 53 lb (24 kg) |
PANEL WEIGHT | MAX |
27" Drawer | 13 lb (6 kg) |
36" Drawer | 16 lb (7 kg) |
PANEL THICKNESS | MIN |
All Panels | 5/8" (16) |
Typical panel dimensions are based on an 81" (2057) finished height for column models, 80" (2032) for tall models and
341/2" (876) for drawer models, with a 4" (102) toe kick and
1/8" (3) reveals. Panel dimensions must be adjusted accord- ingly for all other installations. Refer to the illustration for panel heights and the chart below for panel widths.
PANEL WIDTH
MODEL | W |
27" Model | 263/4" (679) |
36" Model | 353/4" (908) |
DUAL INSTALLATION
For dual installations, refer to the illustration for panel heights and the chart below for panel widths.
PANEL WIDTH
MODEL | W |
27" Model | 2613/16" (681) |
36" Model | 3513/16" (910) |
8