D U C T I N G C O N S I D E R A T I O N S

Planning Information

Model W362418(R) Pro Wall Hood

D U C T I N G C O N S I D E R A T I O N S

Wolf Pro 24" (610) deep wall hoods are shipped without the blower assembly. Internal, in-line or remote blower assemblies are available. The remote blower can be mounted on the roof or an exterior wall. Refer to the illustration below for ducting options.

Pro 24" (610) deep wall hoods have an adjust- able discharge location that can run vertically or horizontally. Horizontal discharge is applicable on 24" (610) deep hoods used with WBLOWER- 60INT or WBLOWER-120INT or any remote blower. WBLOWER-90INT is not for use in hori- zontal discharge applications.

Refer to the Pro ventilation charts at the end of this section for recommendations and blower options.

ROOF CAP OR REMOTE BLOWER

10" ROUND DUCT

SOFIT OR CABINET

OR DUCT COVER

18" (457)

 

WALL HOOD

HEIGHT OF HOOD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24" (610)

DEPTH OF HOOD

30" TO 36"

(762–914)

COUNTERTOP

TO BOTTOM OF

VENTILATION HOOD

DUCTWORK INSTALLATION

THROUGH ROOF

TRANSITION 221/4"W x 9"D TO 10" ROUND 10"H (INCLUDING FLANGES)

VERTICAL DISCHARGE

WALL CAP

OR REMOTE BLOWER

DUCTWORK INSTALLATION

THROUGH WALL

DISCHARGE COLLAR

HORIZONTAL

DISCHARGE*

Ducting considerations for Pro 24" (610) deep wall hoods.

36" (914)

STANDARD

FLOOR TO

COUNTERTOP

HEIGHT

*HORIZONTAL DISCHARGE IS APPLICABLE ON 24" (610) DEEP WALL HOODS USED WITH WBLOWER-60INT, WBLOWER-120INT OR ANY WOLF REMOTE BLOWER. WBLOWER-90INT IS NOT FOR USE IN HORIZONTAL DISCHARGE APPLICATIONS.

Dimensions in parentheses are in

millimeters unless otherwise specified.