Planning Information
Model W362418(R) Pro Wall Hood
D U C T I N G C O N S I D E R A T I O N S
Wolf Pro 24" (610) deep wall hoods are shipped without the blower assembly. Internal,
Pro 24" (610) deep wall hoods have an adjust- able discharge location that can run vertically or horizontally. Horizontal discharge is applicable on 24" (610) deep hoods used with WBLOWER- 60INT or
Refer to the Pro ventilation charts at the end of this section for recommendations and blower options.
ROOF CAP OR REMOTE BLOWER
10" ROUND DUCT
SOFIT OR CABINET
OR DUCT COVER
18" (457) |
| WALL HOOD | ||
HEIGHT OF HOOD |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
24" (610)
DEPTH OF HOOD
30" TO 36"
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
DUCTWORK INSTALLATION
THROUGH ROOF
TRANSITION 221/4"W x 9"D TO 10" ROUND 10"H (INCLUDING FLANGES)
VERTICAL DISCHARGE
WALL CAP
OR REMOTE BLOWER
DUCTWORK INSTALLATION
THROUGH WALL
DISCHARGE COLLAR
HORIZONTAL
DISCHARGE*
Ducting considerations for Pro 24" (610) deep wall hoods.
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
*HORIZONTAL DISCHARGE IS APPLICABLE ON 24" (610) DEEP WALL HOODS USED WITH
Dimensions in parentheses are in
millimeters unless otherwise specified. | 6 |