TROUBLESHOOTING AND REPAIR

F-53

MAIN TRANSFORMER AND OUTPUT CHOKE

REMOVAL AND REPLACEMENT (continued)

Return to Section

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master

Return to Master TOC

Return to Master TOC

Return to Master TOC

11.Unplug and label leads X5, X6, X7, X8, and X9. These leads have connectors near the trans- former which can be disconnected.

12.Disconnect the output choke lead from the posi- tive capacitor bank buss using two 1/2 in. open end wrenches.

13.Remove the other output choke lead from the positive output terminal using a 1/2 in. wrench.

13.Remove all cable ties, wire mounts, and any har- ness type that could get in the way during trans- former removal using wire cutters and screw driver.

14.Remove the four nuts and washers mounting the transformer to the floor of the machine using a 1/2 in. wrench.

15.Carefully remove the main transformer and choke assembly.

16.Reassemble the main transformer and choke assembly in the reverse order.