TROUBLESHOOTING AND REPAIR

F-7

 

 

 

Observe all Safety Guidelines detailed throughout this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

 

No control of arc voltage. Wire feed-

1. The arc voltage control poten-

1. The arc voltage control poten-

ing is normal.

 

tiometer may be dirty. Rotate

tiometer may be faulty. Check or

 

 

several times and check if prob-

replace. See Wiring Diagram.

 

 

lem is resolved.

 

 

 

 

2. Perform the SCR Rectifier

 

 

 

Assembly Tests.

 

 

 

3. The control board may be faulty.

 

 

 

Replace.

 

 

 

There is no gas flow when gun trig-

1. Check gas source and hoses for

1. Check the gas solenoid by dis-

ger is pulled. Wire feeds and weld

 

leaks or kinks.

connecting it from the control

voltage is present.

 

 

board (Plug J8) and applying a

 

 

 

12 VDC external supply to the

 

 

 

gas solenoid. If the solenoid

 

 

 

does NOT activate then it may

 

 

 

be faulty. Replace.

 

 

 

2. The control broad may be faulty.

 

 

 

Replace.

 

 

 

 

The machine stops feeding wire

1.

Check for adequate wire supply.

1. Check the motor armature cur-

while welding.

 

 

rent. Normal armature current is

 

2.

Check for mechanical restric-

2.0 to 2.7 amps maximum. If

 

 

tions in the wire feeding path.

the motor armature current is

 

 

The gun may be clogged.

normal the control board may be

 

 

 

faulty. Replace.

 

3. Check gun liner and tip are cor-

 

 

 

rect for wire size being used.

2. If the motor armature current is

 

 

 

high (over 2.7 amps) and there

 

4. Check spindle for ease of rota-

are NO restrictions in the wire

 

 

tion.

feeding path then the motor or

 

 

 

gear box may be defective.

 

5. If Timer Option Kit is installed,

Replace.

 

 

make sure spot timer knob is

 

 

 

set to OFF.

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.

------------------------------------------------------------------------------------------------------------------------------------------------------

POWER MIG 255C

Page 47
Image 47
Lincoln Electric SVM170-A service manual Function Problems