MAIN TRANSFORMER TEST (continued)

 

Return to Section

Return to Section TOC

TOC

Return to Master

Return to Master TOC

TOC

6.Connect main input power to the machine.

7.Turn the POWER MIG 255C ON/OFF POWER SWITCH to ON.

8.Carefully make the following voltage tests at plug J6.

a.Turn the machine OFF between each test.

b.Carefully insert the meter probes into the back of each Molex plug pin cavity to perform the test.

FROM

TO

EXPECTED

LEAD

LEAD

VOLTAGE

 

 

 

X5

X6

15VAC

(6J6)

(5J6)

 

X5

X7

30VAC

(6J6)

(4J6)

 

X6

X7

15VAC

(5J6)

(4J6)

 

 

 

 

9.Turn OFF the machine.

10.Locate the following leads on plug J5 on the Control PC board. See Figure

11.Turn the machine ON.

12.Make the following voltage tests at plug J5.

a.Turn the machine OFF between each test.

b.Carefully insert the meter probes into the back of each Molex plug pin cavity to perform the test.

FROM

TO

EXPECTED

LEAD

LEAD

VOLTAGE

 

 

 

X8

X9

115VAC

(16J5)

(8J5)

 

 

 

 

c. If the voltage tested is incorrect, check for loose or broken leads between the test points and the main transformer.

d.If the voltage is not corrected, go to step 16.