Section TOC

Master TOC

F-14

TROUBLESHOOTING AND REPAIR

F-14

 

MAIN TRANSFORMER TEST (continued)

 

14.

Locate the following leads on plug J5

d. If ALL the voltages tested are incor-

 

on the Control PC board. See Figure

rect or missing, go to step 16.

 

F.1.

 

 

Return to

Return to

 

PLUG

LEAD

LOCATION

 

 

206

3J5

 

 

17.Test for correct nameplate input voltage between the H1 lead at the ON/OFF POWER SWITCH to H2 or H3 (H5 if connected for 575 VAC) at the reconnect panel. Voltage tested will vary depending on input voltage connection. See wiring diagram for test point locations.

Return to Section TOC

TOC

Return to Master TOC

TOC

 

PLUG

LEAD

LOCATION

2082J5

2091J5

15.

Turn the machine ON.

16.Make the following voltage tests at plug J5 on the Control PC board.

a.Turn the machine OFF between each test.

b.Carefully insert the meter probes into the back of each Molex plug pin cavity to perform the test.

c.If any of the voltages tested are incorrect, check for loose or broken leads between the test points and the main transformer.

a.If the voltage test is incorrect,

-check for loose or broken leads between the reconnect panel and the ON/OFF POWER SWITCH.

-test the ON/OFF POWER SWITCH for proper operation.

b.If the correct nameplate voltage is being applied to the main trans- former and one or more of the sec- ondary voltages are missing or are incorrect, the main transformer may be faulty. Replace.

Return to Section

Return to Section TOC

Return to Master

Return to Master TOC

FROM

TO

EXPECTED

LEAD

LEAD

VOLTAGE

 

 

 

208

209

56VAC

(2J5)

(1J5)

 

208

206

28VAC

(2J5)

 

 

209

206

28VAC

(1J5)

 

 

 

 

 

POWER MIG 255C

Page 54
Image 54
Lincoln Electric SVM170-A service manual 206 3J5