Lincoln Electric SVM170-A F-38, CONTROL PC BOARD REMOVAL AND REPLACEMENT continued, Procedure

Models: SVM170-A

1 109
Download 109 pages 57.27 Kb
Page 78
Image 78
F-38

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-38

TROUBLESHOOTING AND REPAIR

F-38

 

CONTROL PC BOARD REMOVAL AND REPLACEMENT (continued)

 

 

FIGURE F.10 — WIRING HARNESS

REMOVAL AND REPLACEMENT

 

AND MOLEX PLUG LOCATIONS.

PROCEDURE

 

 

J6

1. Disconnect main input power the

 

 

 

J5

machine.

 

 

 

 

 

 

2. Open the side panels and remove the

 

 

tool tray using a 5/16 in. nutdriver.

 

J3

3. Disconnect all wiring harness plugs and

 

J8

Molex plugs connected to the control

 

board. See Figure F.10.

 

 

J1

 

 

 

 

J4

J2

POWER MIG 255C

Page 78
Image 78
Lincoln Electric SVM170-A F-38, CONTROL PC BOARD REMOVAL AND REPLACEMENT continued, Removal And Replacement, Procedure