INSTALLATION

A-3

 

 

 

Return to Master TOC

Return to Master TOC

Read entire installation section before starting installation.

SAFETY PRECAUTIONS

SAFETY PRECAUTIONSWARNING

ELECTRIC SHOCK can kill.

Only qualified personnel should perform this installation.

Only personnel that have read and under- stood the POWER MIG 255C Operating Manual should install and operate this equip- ment.

Machine must be grounded per any national, local or other applicable electrical codes.

The POWER MIG power switch is to be in the OFF position when installing work cable and gun and when connecting other equipment.

------------------------------------------------------------------------

UNCRATING THE POWER MIG 255C

Cut banding and lift off cardboard carton. Cut banding holding the machine to the skid. Remove foam and cor- rugated packing material. Untape accessories from Gas Bottle Platform. Unscrew the two wood screws (at the Gas Bottle Platform) holding the machine to the skid. Roll the machine off the skid assembly.

INPUT POWER, GROUNDING AND CONNECTION DIAGRAMS

UNCRATING THE POWER MIG 255CWARNING

ELECTRIC SHOCK can kill.

Do not touch electrically live parts such as output terminals or internal wiring.

All input power must be electrically discon- nected before proceeding.

------------------------------------------------------------------------

1.Before starting the installation, check with the local power company if there is any question about whether your power supply is adequate for the voltage, amperes, phase, and frequency spec- ified on the welder nameplate. Also be sure the planned installation will meet the U.S. National Electrical Code and local code requirements. This welder may be operated from a single phase line or from one phase of a two or three phase line.

2.Models that have multiple input voltages specified on the nameplate (e.g. 208/230) are shipped con- nected for the highest voltage. If the welder is to be operated on lower voltage, it must be recon- nected according to the instructions in Figure A.1 for dual voltage machines and Figure A.2 for triple voltage machines.

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

LOCATION

Locate the welder in a dry location where there is free circulation of clean air into the louvers in the back and out the front. A location that minimizes the amount of smoke and dirt drawn into the rear louvers reduces the chance of dirt accumulation that can block air pas- sages and cause overheating.

INPUT POWER, GROUNDING AND CONNECTION DIAGRAMS WARNING

Make certain that the input power is electrically disconnected before removing the screw on the reconnect panel access cover.

------------------------------------------------------------------------

POWER MIG 255C

Page 9
Image 9
Lincoln Electric SVM170-A Safety Precautions, UNCRATING THE POWER MIG 255C, Input Power, Grounding And Connection Diagrams