F-52TROUBLESHOOTING AND REPAIRF-52

MAIN TRANSFORMER AND OUTPUT CHOKE

REMOVAL AND REPLACEMENT (continued)

FIGURE F.17 — MAIN TRANSFORMER REMOVAL.

Return to Section TOC

Return to Master TOC

LEAD

X1

OUTPUT

CHOKE POSITIVE

LEAD

OUTPUT

CHOKE

LEAD

NOTE: PLUG-IN LEADS ARE NOT SHOWN FOR CLARITY.

LEAD X4

LEADS

X2 AND X3

Section TOC

Master TOC

MAIN

TRANSFORMER

POWER

ENHANCEMENT

CHOKE

Return to

Return to Section TOC

Return to

Return to Master TOC

PROCEDURE

1.Disconnect main input power to the machine.

2.Remove the case side panels using a 3/8 in. nutdriver.

3.Test that the capacitors are discharged using a volt ohmmeter. Polarity must be observed.

4.Remove lead X1 from the left side SCR heat sink assembly using a 1/2 in. sock- et wrench, extender and universal adapter. See Figure F.17.

5.Remove lead X4 from the right side heat sink assembly using a 1/2 in. sock- et wrench, extender and universal adapter.

6.Remove the two transformer secondary leads X2 and X3 (braided copper strap) from the negative capacitor bank buss bar using two 1/2 in. open end wrench- es.

7.Disconnect and label all transformer leads from the reconnect panel using a 3/8 in. open end wrench.

8.Disconnect and label all leads from the input power switch.

9.Remove the power switch.

10.Disconnect thermostat leads #320 and #320B from the SCR Rectifier.

POWER MIG 255C

Page 92