F-6

TROUBLESHOOTING AND REPAIR

F-6

 

 

 

Observe all Safety Guidelines detailed throughout this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

OUTPUT PROBLEMS (Continued)

 

 

 

 

 

 

 

The output voltage and wire feed is

1.

Remove the gun. If the problem

1.

Check the machine's internal

present continuously or pulsing

 

is resolved the gun trigger circuit

 

trigger leads for grounds or

when gun trigger is NOT activated.

 

is faulty. Repair or replace.

 

shorts. See Wiring Diagram.

 

2.

If problem persists when gun

2.

The control board may be faulty.

 

 

assembly is removed from

 

Replace.

 

 

machine, then the problem is

 

 

 

 

within the POWER MIG 255C.

 

 

 

 

 

 

The output voltage is present contin-

Contact your local Lincoln Electric

1.

Perform the SCR Rectifier

uously when gun trigger is NOT acti-

Authorized Field Service Facility.

 

Assembly Tests.

vated.

 

 

 

 

 

 

 

2.

The control board may be faulty.

 

 

 

 

Replace.

 

 

 

 

 

Manual backgroundCAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.

------------------------------------------------------------------------------------------------------------------------------------------------------

POWER MIG 255C

Page 46