Lincoln Electric SVM170-A Scr Operation, Theory Of Operation, Return to Section, Return to Master

Models: SVM170-A

1 109
Download 109 pages 57.27 Kb
Page 39
Image 39
Return to Section

TOC

TOC

E-7

THEORY OF OPERATION

E-7

 

 

 

 

FIGURE E.6 — SCR OPERATION.

 

INPUT

CATHODE

OUTPUT

ANODE

GATE

NOTE: AS THE GATE PULSE IS APPLIED LATER IN THE CYCLE THE SCR OUTPUT IS DECREASED.

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

SCR OPERATION

A silicon controlled rectifier (SCR) is a three terminal device used to control rather large currents to a load. An SCR acts very much like a switch. See Figure E.6 for a graphical representation of SCR operation. When a gate signal is applied to the SCR it is turned ON and there is current flow from anode to cathode. In the ON state the SCR acts like a closed switch. When the SCR is turned OFF there is no current flow from anode to cathode thus the device acts like an open switch. As the name suggests, the SCR is a rectifier, so it passes current only during positive half cycles of the AC sup- ply. The positive half cycle is the portion of the sine wave in which the anode of the SCR is more positive than the cathode.

When an AC supply voltage is applied to the SCR, the device spends a certain portion of the AC cycle time in

the off state and the remainder of the time in the on state. The amount of time spent in the ON state is con- trolled by the gate.

An SCR is fired by a short burst of current into the gate. This gate pulse must be more positive than the cath- ode voltage. Since there is a standard PN junction between gate and cathode, the voltage between these terminals must be slightly greater than 0.6V. Once the SCR has fired it is not necessary to continue the flow of gate current. As long as current continues to flow from anode to cathode the SCR will remain on. When the anode to cathode current drops below a minimum value, called holding current, the SCR will shut off. This normally occurs as the AC supply voltage passes through zero into the negative portion of the sine wave. If the SCR is turned on early in the positive half cycle, the conduction time is longer resulting in greater SCR output. If the gate firing occurs later in the cycle the conduction time is less resulting in lower SCR output.

POWER MIG 255C

Page 39
Image 39
Lincoln Electric SVM170-A service manual Scr Operation, Theory Of Operation, Return to Section, Return to Master