6.Disconnect leads X2 and X3 (braided copper strap) from the negative capaci- tor bank buss bar using a 1/2 in. open end wrench. See Figure F.7.
FIGURE F.7 — LOCATION OF
LEADS X2 AND X3.
NEGATIVE
CAPACITOR
BANK BUSS
BAR
8.Use a commercial SCR tester or con- struct the tester circuit shown in Figure F.8. One
a.Test the voltage level of the battery. Short leads (A) and (C). Close switch
FIGURE F.8 — SCR TESTER CIRCUIT
AND SCR CONNECTIONS.
Return
Return to Section TOC
Return to Section TOC
LEADS X2 AND X3
CONNECTION
7.Separate leads X2 and X3 from the negative capacitor bank buss bar. Be sure there is no electrical contact.
NOTE: DO NOT DISASSEMBLE THE SCR RECTIFIER HEAT SINK ASSEMBLY.