Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
F-16 TROUBLESHOOTING AND REPAIRF-16
RECTIFIER DIODE BRIDGE TESTING (continued)
FIGURE F.2 — G3521 RECTIFIER DIODE BRIDGE LOCATION.
RECTIFIER
DIODE BRIDGE
(D2)
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
TEST PROCEDURE
1.Disconnect the main AC input power to the machine.
2.Remove the case top and side panels with a 3/8 in. nutdriver.
3.Perform the Main Transformer Test to ensure the proper voltages are supplied to the J5 plug on the Control board.
4.Locate the following leads:
LEAD
208
209
354
206
Leads #208, #209, and #354 are con- nected to the rectifier diode bridge (D2). See Figure F.2. Lead #206 is connect- ed at the output shunt. See the wiring diagram.
5.Connect main input power to the machine.