ACTIVE SCR RECTIFIER ASSEMBLY TEST (continued)

 

FIGURE F.6 — CONTROL BOARD MOLEX PLUG LOCATIONS FOR G3521 PC CONTROL BOARD.

J6

J5

J3

J8

J1

J4

J2

TEST PROCEDURE

Return to

Return to Section TOC

Return to

Return to Master TOC

1.Disconnect main AC input power to the machine.

2.Remove the case top and side panels with a 3/8 in. nutdriver.

3.Remove the tool tray with a 5/16 in. nut- driver.

4.Verify that the capacitors have completely discharged with a volt-ohmmeter.

5.Disconnect plugs J6 and J5 control board. This electrically isolates the SCR bridge assembly. See Figure F.6.