6.Turn the POWER MIG 255C ON/OFF POWER SWITCH to ON.

7.Carefully make the following voltage tests:

a.Turn the machine OFF between each test.

b.Carefully connect the meter plugs to the exposed lead connections.

c.Turn the machine ON to conduct the voltage test at J5 connector Control board

FROM

TO

EXPECTED

LEAD

LEAD

VOLTAGE

 

 

 

208

206

28 VAC

209

206

28 VAC

 

 

 

8.If any of the AC voltages tested are incorrect or missing, check the leads and connections. See the wiring dia- gram.

9. Make the following voltage test:

a. Turn the machine OFF between each test.

b. Carefully connect the meter probes to the exposed lead connections.

c. Turn the machine ON to conduct the voltage test.

FROM

TO

EXPECTED

LEAD

LEAD

VOLTAGE

 

 

 

354

206

36 VDC

 

 

 

10. If the DC voltage tested is incorrect or missing, and the AC voltages are cor- rect, the rectifier diode bridge may be faulty.