Jenn-Air W10274319E, W10272061 Installation Requirements, Tools and Parts, Location Requirements

Models: W10274319E W10272061

1 28
Download 28 pages 2.83 Kb
Page 5
Image 5
INSTALLATION REQUIREMENTS

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Tools needed

Level

Drill with 1¼" (3.0 cm), ³⁄₈" (9.5 mm), ⁷⁄₆₄" (2.75 mm) and ¹⁄₈" (3.0 mm) drill bits

Pilot hole drill bits (determined by chimney support attachment method)

Pencil

Wire stripper or utility knife

Tape measure or ruler

Pliers

Caulking gun and weatherproof caulking compound

Vent clamps

Jigsaw or keyhole saw

Flat-blade screwdriver

Metal snips

Phillips screwdriver

Parts needed

Home power supply cable

2 - ½" (12.7 mm) UL listed or CSA approved strain reliefs

3 UL listed wire connectors

For vented installations, you will also need:

1 wall or roof cap

Metal vent system

For non-vented (recirculating) installations, you will also need:

Recirculating Kit Part Number W10272061 for non-vented

(recirculating) installations only. See “Assistance or Service”

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

Have a qualified technician install the range hood. It is the installer's responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located behind the left filter on the rear wall of the vent hood.

Canopy hood location should be away from strong draft areas, such as windows, doors and strong heating vents.

Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance.

Grounded electrical outlet is required. See “Electrical Requirements” section.

Because of the size and weight of this island hood, the chimney support must be securely attached to the ceiling.

For plaster or drywall ceilings, the chimney support must be attached to joists. If this is not possible, you must build a support structure behind the plaster or drywall. The support structure must be able to support 80 lbs (36.6 kg).

The range hood is factory set for venting through the roof.

For non-vented (recirculating) Installation see “Non-vented (recirculating) Installations” in “Install Range Hood” section. Recirculation Kit Part Number W10272061 is available from your dealer or an authorized parts distributor.

All openings in ceiling and wall where range hood will be installed must be sealed.

For Mobile Home Installations

The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local codes.

Product Dimensions

section to order.

8" (20.3 cm) round metal vent duct. Length required is

determined by ceiling height.

Parts supplied

Remove parts from packages. Check that all parts are included.

Hood canopy assembly with ventilator and light bulbs

installed

Filter - installed in hood canopy

68 - 4 x 8 mm screws

4 - 5 x 45 mm screws

Mounting template

12¹⁄₄"

(31.0 cm)

13³⁄₁₆"

(33.5 cm)

*32¹⁄₂" **32¹⁄₂"

(82.6 cm) (82.6 cm)

min. min.

*46¹⁄₂" **52⁹⁄₁₆"

(118.0 cm) (133.5 cm)

max. max.

4 vent covers with 4 trim pieces

36" (91.2 cm)

42" (106.4 cm)

27" (68.6 cm)

 

 

 

*Vented installations only

**Non-vented (recirculating) installations only

5

Page 5
Image 5