Jenn-Air W10272061 Install Range Hood, Range Hood Mounting Screws Installation, B A A, A A B

Models: W10274319E W10272061

1 28
Download 28 pages 2.83 Kb
Page 8
Image 8
Range Hood Mounting Screws Installation

Range Hood Mounting Screws Installation

1.Determine and mark the centerline on the ceiling where the range hood will be installed, considering the requirements for ceiling support structures. See the “Location Requirements” section. Make sure the range hood is centered over the cooking surface.

2.Tape template in place on the ceiling at the marked centerline.

3.Use a pencil to mark the mounting screws, wire access and duct hole locations on the ceiling.

NOTE: Mounting hole locations should be into the ceiling support structure.

Remove the template.

4.Drill 4 - ³⁄₁₆" (4.8 mm) pilot holes for mounting the upper horizontal support.

Complete Preparation

1.Determine the required location for the home power supply cable and drill a ½" (1.3 cm) diameter hole for wire access.

2.Run wire through the home power supply cable according to the National Electrical Code or CSA Standards and local codes and ordinances. There must be enough ½" conduit and wires from the fused disconnect (or circuit breaker) box to make the connection in the hood’s electrical terminal box.

NOTE: Do not reconnect power until installation is complete.

3.Use caulk to seal all openings.

4.For vented installations only: Using a jigsaw or keyhole saw, cut a 8½" (21.6 cm) diameter hole for the vent duct.

5.Attach the upper horizontal support bracket with 4 - 5 x 45 mm wood screws.

A

A. Upper horizontal support

Install Range Hood

1.Position the vertical supports (A) with notches at the bottom and attach to the range hood using 16 - 4 x 8 mm screws.

2.Attach the horizontal support (B) using 8 - 4 x 8 mm screws.

B

A A

A. Vertical supports

B. Horizontal support

3.Attach a second set of vertical supports (A) and set the vertical height (B). See “Installation Dimensions” in the “Location Requirements” section to help determine the desired dimension for the vertical height “B.”

A A

B

A. Vertical suppoarts

B. Vertical height

4.Attach the range hood assembly to the upper horizontal support attached to the ceiling using 16 - 4 x 8 mm screws and tighten.

A

A. Mounting screws

8

Page 8
Image 8
Jenn-Air W10272061 Install Range Hood, Range Hood Mounting Screws Installation, Complete Preparation, B A A, A A B