6.Use UL listed wire connectors and connect white wires (E) together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire in terminal box.
Failure to do so can result in death or electrical shock.
7.Connect green (or bare) ground wire from home power supply to
8.Tighten strain relief screw.
9.Install terminal box cover.
10.Check that all light bulbs are secure in their sockets.
11.Reconnect power.
Install Duct Covers
1.Attach the vertical duct cover supports using 4 - 4 x 8 mm screws.
3.Attach lower duct covers using a plastic bracket at each corner (4 needed).
A
B
C
A. Upper duct cover
B. Lower duct cover
C. Plastic bracket
Complete Installation
1.For
2.Install metal filters. See the “Range Hood Care” section.
3.Check the operation of the range hood blower and light. See the “Range Hood Use” section.
If range hood does not operate, check to see whether a circuit breaker has tripped or a household fuse has blown.
NOTE: To get the most efficient use from your new range hood, read the “Range Hood Use” section.
A
B
A
A.Screws
B.Vertical duct cover support
2.Slide upper duct covers into place until springs “click.”
A
B
A. Upper duct cover
B. Spring
RANGE HOOD USE
The range hood is designed to remove smoke, cooking vapors and odors from the cooktop area. For best results, start the hood before cooking and allow it to operate several minutes after the cooking is complete to clear all smoke and odors from the kitchen.
The range hood controls are located on the front side of the canopy.
A
B
| G |
C |
|
| F |
D |
|
E |
|
A. Louver holes | D. Canopy |
[recirculating] installations only) | E. Grease filters |
B. Duct covers | F. Grease filter handles |
C. Lamp housings | G. Control panel |
10