TROUBLESHOOTING AND REPAIR

F-11

TEST PROCEDURES

MAIN TRANSFORMER TEST

TEST PROCEDURESWARNING

Service and repair should only be performed by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in dan- ger to the technician or machine operator and will invalidate your factory war- ranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to per- form the test/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.

-------------------------------------------------------------------------------------------------------------------

TEST DESCRIPTION

This test will determine if the correct voltages are being:

a.Applied to the primary windings of the main transformer.

b.Induced on the secondary and auxiliary windings of the main transformer.

MATERIALS NEEDED

3/8 in. Nutdriver 5/16 in. Nutdriver Volt-ohmmeter