Lincoln Electric SVM170-A F-45, Scr Output Rectifier Removal And Replacement, Description

Models: SVM170-A

1 109
Download 109 pages 57.27 Kb
Page 85
Image 85
F-45

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-45

TROUBLESHOOTING AND REPAIR

F-45

SCR OUTPUT RECTIFIER REMOVAL AND REPLACEMENT

SCR OUTPUT RECTIFIER REMOVAL AND REPLACEMENTWARNING

Service and repair should only be performed by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in dan- ger to the technician or machine operator and will invalidate your factory war- ranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to per- form the test/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.

-------------------------------------------------------------------------------------------------------------------

DESCRIPTION

The procedure will aid the technician in the removal and replacement of the SCR assembly.

MATERIALS NEEDED

1/2 in. Open end wrench

1/2 in. Socket wrench, universal tool, and extension 3/8 in. Nutdriver

3/8 in. Open end wrench

POWER MIG 255C

Page 85
Image 85
Lincoln Electric SVM170-A F-45, Scr Output Rectifier Removal And Replacement, Troubleshooting And Repair, Description