The following tables list problems that could occur when using the granulator. This general information may help to locate the cause of the problem and allow it to be resolved promptly. When a problem arises, it is advisable to perform the simplest checks before proceeding to more complicated ones, which may subsequently prove unnecessary.

7-1

General Problems

 

 

 

 

 

 

 

 

 

 

 

 

 

Problem

 

 

Possible Causes

 

 

Possible Remedies

 

 

Overheating of bearings

Dirt or contamination in the bearing

 

Correct source of contamination

 

 

 

 

Excessive belt tension

 

Adjust belt tension

 

 

 

 

No lubrication

 

 

 

 

 

 

Check bearing seals

 

 

 

 

 

 

 

 

 

Knives moving in their

There may be foreign matter on the

 

Carefully clean seat

 

seats

 

 

knives

 

 

 

 

 

 

 

Knife screws loose

 

Tighten screws with torque wrench

 

 

 

 

 

 

 

 

at values specified

 

 

 

 

Knife screws weakened

 

Screws must not be used more than

 

 

 

 

 

 

 

 

6 times

 

Broken knife

 

 

 

Improper resharpening

 

Check knife grinding method used

 

 

 

 

Extremely hard material

 

Contact supplier

 

 

 

 

 

Check rotor direction

 

 

 

 

Incorrect rotor direction

 

 

 

 

 

 

Look for cause with operator

 

 

 

 

Foreign body in the cutting chamber

 

 

 

 

 

 

 

 

 

 

 

 

Faulty fitting of screen

 

Check assembly procedure

 

Excessive knife wear

Incorrect knife position

 

Correct the gap or distance

 

 

 

 

 

 

 

 

between bed knives and rotor

 

 

 

 

 

 

 

 

knives

 

 

 

 

Improper knife re-sharpening

 

Check dimensions with Figure 14

 

 

 

 

 

 

 

 

and Figure 15.

 

 

 

 

Abrasive material

 

Contact the supplier for special

 

 

 

 

 

 

 

 

knives

 

Abnormal screen wear

Incorrect fitting of screen

 

Check that the screen is correctly

 

 

 

 

 

 

 

 

seated in its rear position and that it

 

 

 

 

 

 

 

 

fits perfectly at the front.

Page 41 of 54

Page 41
Image 41
Sterling BP810, BP814, BP818 manual 7Troubleshooting, General Problems, Possible Causes, Possible Remedies