!!Caution!!
Before connecting the power, check that the power cable size and capacity corresponds to the horsepower and amp load indicated on the granulator label and that the disconnect switch is in the OFF position. (See Figure 2.)
Unless otherwise specified, the granulator has been wired for 480 volts, 60 Hz, 3 ph.
The power cable from the plant source can be run directly to the control panel or through the base of the machinery. To run the power cable through the base of the granulator, perform the following steps:
1.Open the back cover, and insert the power cable from underneath the granulator.
2.Pass the power cable through the appropriate hole, and insert it into the control panel through a connector placed at the base.
3.Connect the three phase wires to the appropriate terminals of the main switch, and connect the ground wire to the terminal provided near the main disconnect switch. (See Figure 7.)
Figure 7: Electrical Connections
Phase Wire
Terminals
4-4 Start-Up Checks
4-4-1 Checking the Cutting Chamber
Before starting the granulator, open the cutting chamber to ensure that during transportation or installation, no foreign objects have
Page 24 of 54