10.When adjustment is complete, tighten the lock nuts on the adjustment screws.
11.Torque the bed knife and bed knife shield bolts to 95 lbs./ft. (13 Kgm., 128 Nm) using a torque wrench.
12.Repeat the steps
13.Close the hopper and replace the screen and screen cradle, securing them in place using the swing bolt provided.
14.Close the front and rear doors, and unlock the power or replace the fuses in the control panel. Turn the disconnect switch to “ON”.
Figure 13: Inspection of Knives
Rotor Knife Locking Bolts
Bed Knife Locking Bolts
Bed knife Adjusting Screws
6-5 Removing and Replacing Bed Knives
NOTE: This procedure should be performed by a qualified operator / maintenance mechanic. Protective gloves must be worn to avoid injury when handling the cutting knives.
To remove and replace bed knives, complete the following procedure:
1.Open the granulator by following Steps
2.Open the
Page 36 of 54