13. Close the machine, following Steps
6-6 Removal and Replacement of Rotating Blades
NOTE: A qualified operator / maintenance mechanic should perform this operation. Protective gloves must be worn to avoid injury when handling the cutting knives.
To remove and replace rotor knives, complete the following procedure:
1.Open the granulator by following Steps
2.Open the
3.Pivot the
4.Rotate the rotor so that the knife bolts are in a convenient position to remove the bolts with the appropriate wrench. Using a wooden block, block the rotor to prevent it from rotating while removing knives or after a knife has been removed.
5.Loosen and remove the knife bolts and lift the knife off the knife seat removing it from the cutting chamber.
6.Perform the above steps until all the rotor knives are removed.
NOTE: Before replacing the rotor knife with new or sharpened knives, wipe the knife seats on the rotor, being sure to clean off all process material. The tapped holes in the rotor (used for holding the knives in place) should be clear of any dirt, oil, or process material.
7.Loosen the bed knife bolts and adjusting screws, and pull back the bed knife so that the rotor knives will collide as they are installed and rotated.
8.Install new or sharpened knives on each knife seat, making sure that the rotor is still blocked to prevent it from rotating while installing each knife.
9.Before