Electrical Problems |
|
| ||
|
|
|
| |
Problem | Possible Causes |
| Possible Remedies | |
Machine stops for no | Safety switch has stopped power |
| Check that the knobs that operate | |
apparent reason |
|
| the safety switch are tightened | |
|
|
|
| |
Electric motor does not | No power |
| Check fuses | |
start |
|
|
|
|
|
| Overload failure |
| Check amperage of electric motor |
|
| Safety switch not working |
| Check and replace |
|
|
| Empty cutting chamber | |
|
| Cutting chamber too full |
| |
|
|
|
| |
Motor starts but does not | Excessive drive belt tension |
| Check belt tension and adjust | |
speed up or take a load |
|
|
| |
|
| Motor connected to power source |
| Reconnect correctly |
|
| incorrectly |
|
|
|
| Defective starter winding |
| Check current in each phase. If |
|
|
|
| substantial difference between |
|
|
|
| phases, contact motor manufacturer |
|
|
|
| |
Motor starts, but does not | Bearing excessively worn |
| Replace bearings | |
gain speed |
|
|
|
|
|
| Cutting chamber full |
| Empty cutting chamber |
Page 43 of 54