MAINTENANCE

Removing The Sear Station® Burner

To remove the Sear Station Burner®, pull the burner tube toward you.. This removes it from the burner tube notch (7).. Then rotate the tube clockwise (8), taking care to rotate it so that the screw at the end of the tube (9) fits through the notch in the heat shield opening (10). When the burner tube is free, remove it from the cookbox (11)..

A)To reinstall the manifold assembly, reverse steps for “Removing Control Panel” as previously described..

m CAUTION: The burner openings (12) must be positioned properly over the valve orifices (13). Make sure the opposite end of the burner tubes (14) properly align into the slots on the backside of the cookbox. Check proper assembly before fastening manifold in place.

m WARNING: After reinstalling the gas lines, they should be leak checked with a soap and water solution before using the grill. (See “CHECK FOR GAS LEAKS.”)

SIDE BURNER MAINTENANCE

mWARNING: All gas controls and supply valves should be in

the OFF position.

Make sure black wire is connected between the igniter and electrode..

Make sure white wire is connected between the igniter and grounding clip..

Spark should be a white/blue color, not yellow..

A) Igniter wire (1)

B)Ground wire (2)

C)Burner (3)

Side Burner Grate

Side Burner Cap

Side Burner Ring & Head

Igniter Electrode

Control Knob

Igniter

71

28

115

39

104

132 12

143

3

2 1

1

2

34

Page 34
Image 34
Summit 56209 manual Side Burner Maintenance, OFF position, Removing The Sear Station Burner