GAS INSTRUCTIONS
INSTALL GAS SUPPLY
General Specifications for Piping
Note: Contact your local municipality for building codes regulating outdoor gas barbecue installations. In absence of Local Codes, you must conform to the latest edition of the National Fuel Gas Code: ANSI Z 223.1/NFPA 54, or CAN/
INSTALLATION BE DONE BY A PROFESSIONAL.
Some of the following are general requirements taken from the latest edition of the National Fuel Gas Code: ANSI Z 223..1/NFPA 54, or
•This barbecue is designed to operate at 4.5" of water column pressure (.163 psi).
•A manual
•An additional manual
•The quick disconnect connects to a 1/2" NPT thread from the gas source. The quick disconnect fitting is a
•The quick disconnect fitting can be installed horizontally, or pointing downward.
Installing the fitting with the open end pointing upward can result in collecting water and debris..
•The dust covers (supplied plastic plugs) help keep the open ends of the quick disconnect fitting clean while disconnected..
•Pipe compound should be used which is resistant to the action of natural gas when connections are made..
•The outdoor connector must be firmly attached to rigid, permanent construction.
mWARNING: Do not route the 10 foot hose under a deck. The hose must be visible.
Gas Line Piping
•For the correct size and length of gas line piping refer to the latest edition of the
National Fuel Gas Code: ANSI Z 223..1/NFPA 54, or
•Gas piping may be copper tubing, type K or L; polyethylene plastic tube, with a minimum wall thickness of .062"; or standard weight (schedule 40) steel or wrought iron pipe..
•Copper tubing must be
•Plastic tubing is suitable only for outdoor, underground use.
•Gas piping in contact with earth, or any other material which may corrode the piping, must be protected against corrosion in an approved manner..
•Underground piping must have a minimum of 18" cover.
Test Connections
All connections and joints must be thoroughly tested for leaks in accordance with local codes and all listed procedures in the latest edition of the National Fuel Gas Code: ANSI Z 223..1/NFPA 54, or
mDANGER
Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for gas leaks. This will result in a fire or explosion which can cause serious bodily injury or death and damage to property. ◆
This is a typical installation of a Weber® natural gas barbecue.
Local codes may require different installations.
INSIDE WALL
1 | Gas Supply | 2 | Shut Off |
|
|
|
|
OUTSIDE WALL
3 | 4 | 1/2" Pipe Nipple | |
|
|
|
|
5 | Locking Shut Off | 6 | Do Not Use |
|
|
|
|