GAS SUPPLY

BUILT-IN GAS LINE LOCATIONS

Note: Leave an access in the“island” structure for gas supply and regulator service that is not inside the grill structure.

Note: Area should be kept clear of sharp, jagged, or extremely abrasive surfaces to avoid possible damage to gas supply lines. Exercise caution when pulling gas lines through built-in structure.

TYPICAL BULK PROPANE GAS SUPPLY INSTALLATION

We recommend that this installation be done by a LICENSED professional.

GENERAL SPECIFICATIONS FOR PIPING

Note: Contact your local municipality for building codes regulating outdoor gas grill installations. In absence of Local Codes, you must conform to the latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54, Natural Gas and Propane Installation Code, CSA B149.1, or Propane Storage and Handling Code, B149.2, or the Standard for Recreational Vehicles,ANSI A 119.2/NFPA 1192, and CSA Z240 RV Series, Recreational Vehicle Code, as applicable.

This grill is designed to operate at 11 inches of water column pressure. An LP in line regulator may be necessary for this pressure.

mCAUTION: If young children are in the area, a locking valve should be considered.

Pipe compound should be used which is resistant to the action of liquid propane gas when gas connections are made.

The gas connections must be firmly attached to rigid, permanent construction.

Note: The information provided in this manual is general for typical installations. We cannot cover all possible installation ideas. We recommend, prior to installation, that you contact your municipality for local building codes and your local fire department for installation verification.

If you have any questions, contact Customer Service at 1-800-446-1071.

BUILT-IN GAS LINE LOCATIONS

 

 

1

a

 

 

 

 

2

3

 

 

 

1

 

 

 

 

 

2

 

 

 

 

3 c

 

 

 

b

 

460

660

TOLERANCES

1

16 1/2" (419.1 mm)

16 1/2" (419.1 mm)

±1/8" (3.2 mm)

2

11 1/8" (282.6 mm)

11 1/8" (282.6 mm)

±1/8" (3.2 mm)

3

2 1/2" (63.5 mm)

2 1/2" (63.5 mm)

±1/8" (3.2 mm)

a

 

Plan view right

 

b

 

Side view

 

c

 

Gas inlet

 

www.weber.com® 23

Page 23
Image 23