Sun Microsystems PCI manual Other Useful Utilities, cfgadm

Models: PCI

1 50
Download 50 pages 32.77 Kb
Page 46
Image 46
■Check the system log or console for Tavor driver error messages.

If an InfiniBand software package is not installed, check your Solaris Operating System documentation for software package information.

Check the system log or console for Tavor driver error messages.

See tavor(7D) for error messages and descriptions. When the driver is attached to a port on the adapter, the following message is sent.

tavorn: port m up (link width 4x).

In the message, n is the instance of the Tavor device number and m is the port number on the adapter.

One way to check Tavor messages is by typing the following command:

#dmesg grep tavor

Other Useful Utilities

These utilities can display status and other information about InfiniBand devices:

cfgadm

snoop

netstat

kstat

cfgadm

The cfgadm utility displays status and other information about the IB-HCA and IB fabric. See cfgadm_ib(1M) for details. For example:

# cfgadm -al

 

 

 

 

 

Ap_Id

Type

Receptacle

Occupant

Condition

hca:21346543210a987

IB-HCA

 

connected

configured

ok

ib

IB-FABRIC

connected

configured

ok

ib::80020123456789a

IB-IOC

 

connected

configured

ok

ib::802abc9876543

IB-IOC

 

connected

unconfigured unknown

ib::80245678,ffff,ipib

IB-VPPA

 

connected

configured

ok

ib::12245678,0,nfs

IB-PORT

 

connected

configured

ok

ib::21346543,0,hnfs

IB-HCA_SVC

connected

configured

ok

ib::sdp,0

IB-PSEUDO

connected

configured

ok

 

 

 

 

 

 

26 Sun Dual Port 4x IB Host Channel Adapter PCI-X Installation and User’s Guide • September 2005