X I I . M A I N T E N A N C E

E. PNEUMATIC TIRES

1.Do not use this chair if any of the tires in under- or over-inflated.

2.Low pressure in a tire may cause the chair to veer to one side and result in loss of control.

3.An over-inflated tire may burst.

4.Never use a gas station pump to inflate a tire. Such pumps provide air at high volume, and may cause tire to burst.

1.Check for signs of wear and correct air pressure in pneumatic tires weekly.

2.For best performance, inflate tires to the same pressure level, as shown on the tire sidewall:

8" pneumatic casters - 30 to 40 psi

12" pneumatic drive wheels - 35 to 45 psi

3.Caution:

To prevent tire damage:

Use a hand pump (or a low volume air pump) to inflate tires.

Use a tire gauge to check pressure.

F. TO REPAIR OR REPLACE A TIRE

Residual air pressure in tires can cause severe injury. Make sure you release all air in tire before attempting to service or repair tires.

X I I . M A I N T E N A N C E

2.12" Drive Wheels:

a.Elevate and securely support chair so that wheel is off the ground. Release all air from tire.

b.Remove plastic dome plug.

c.Remove lock nut and tab washer.

d.Remove wheel.

e.Repair or replace inner tube.

f.Install wheel on chair by replacing center tab washer and locknut. Use a torque setting of 35 ft.-lbs. to re-tighten nuts. Install plastic dome plug.

g.Inflate tire to proper pressure level (listed on tire sidewall).

G. MOTOR BRUSHES

Check the motor brushes every three (3) months for wear.The brushes should be clean and shiny. Replace worn or blackened brushes.

H. ORDERING PARTS

When you order parts, provide the following:

1.Model of chair

2.Serial number of chair

3.Left hand or right hand control

4.Part number, description and quantity of parts you need.

5.State reason for replacement.

I.MAINTENANCE CHART

You should check the items on this chart at the indicated intervals. If any of the items are loose, worn, bent or distorted, immediately have them checked and/or repaired by your authorized Sunrise supplier. Frequent maintenance and servicing will improve performance and extend wheelchair life.

1.8" Caster Wheels:

a. Release all air from tire.

b. Remove caster wheel from fork.

c.Make sure there is no residual air in tire before you remove bolts that hold the two rim halves together.

d.Remove four bolts from rim. Separate two halves of rim.

e.Repair or replace inner tube.

f.Reassemble the caster wheel; make sure the bearing spacer is in place and all four bolts are secure.

Note: Use a torque setting of 240 inch- pounds when tightening bolts.

g.Mount caster wheel onto fork. Replace washers correctly.

h.Inflate fire to proper pressure level.

CHECK...

Charge Batteries

Check tires for proper inflation level

Check batteries for proper electrolyte level (wet only)

Check plugs and connectors for proper connections

Check all moving parts for wear

Inspect all nuts, bolts and fasteners for looseness or wear

Inspect upholstery for wear

Remove and inspect motor brushes

Servicing by authorized Supplier

Daily Weekly Monthly

Quar

Annually

terly