STA-800D/1000D Equipped Subs | SVSound™ |
Integrated Function Controller
To disable the HPF, rotate the IFC knob until the message “HIGH PASS DISABLE?” is displayed. Single-click the IFC knob to disable the HPF, and single-click again to get to the top-level menu. If the HPF disable feature is selected accidentally, double-click the IFC knob to return to the top-level menu.
Low Pass Filter (LPF) Adjustment
The LPF Function sets the frequency and slope for the low frequencies that will be played by the subwoofer. From the IFC WELCOME screen, single-click the IFC knob and rotate the IFC knob two clicks clockwise until the display reads “MENU/LOW PASS”. Single-click the IFC knob to get to the LPF Function menu. If the LPF is disabled, a message to that effect will be displayed.
If the LPF is disabled, turn the IFC knob clockwise which will display the Low Pass Frequency menu. To set the LPF frequency to a value other than what is currently displayed, single-click the IFC knob and then rotate the knob clockwise or counter-clockwise to set the desired frequency. Frequency choices include 31, 40, 50, 63, 80, 100, and 125Hz.
Single-click the IFC knob to return to the Low Pass Function menu. Turn the IFC knob to move to the Low Pass Slope submenu and single-click to change the slope value. The Low Pass Slope defines the slope of the attenu- ationcurve above the selected frequency. Two choices are available; 12 dB per octave and 24 dB per octave.
To disable the LPF, rotate the IFC knob until the message “LOW PASS DISABLE?” is displayed. Single-click the IFC knob to disable the LPF, and single-click again to get to the top-level menu. If the LPF disable feature is selected accidentally, double-click the IFC knob to return to the top-level menu.
Phase Degree
The Phase Degree Function allows the adjustment of timing for the arrival of bass information from the subwoofer to the listening position. This allows for a finer degree of subwoofer integration with the main speakers.
From the IFC WELCOME screen, single-click the IFC knob and rotate the IFC knob three clicks clockwise until the display reads “MENU/PHASE DEGREE”. Single-click the IFC knob to select the Phase Degree Function. Rotate the IFC knob to select the appropriate value and single-click to select. If the Phase Degree Function is selected ac- cidentally, double-click to return to the top-level menu.
The range of adjustment of this control is 0 degrees to 180 degrees in 15 degree increments.
© 2011 Specialty Technologies, LLC • Call SVSound™ 877.626.5623 • www.svsound.com