System Works 99101100 manual Section Iv. Installation, inlet, Detail A

Models: 99101100

1 15
Download 15 pages 61.98 Kb
Page 4
Image 4
SECTION IV. INSTALLATION

6.Insert the Check Valve into the outlet port

approximately 3/4" to 1" deep making sure the rubber diaphragm facing outward (towards you), see Diagram 1.

7.

Reconnect the return hose to the outlet port and

 

 

 

tighten the union fitting.

 

 

8.

Replace the drain cap.

 

 

 

 

9.

Remove the rag from the skimmer or open the

 

 

 

valve on the suction line.

 

 

10.

If the return line was plugged, unplug it at this time.

Diagram1.

 

 

11.With the High Flow™ manual air relief valve in the

open position, start the filter pump, after a steady stream of water appears close the High Flow™ manual air relief valve.

12.Your system is now in operating order.

SECTION IV. INSTALLATION

To install this filter system, you will need the following simple tools - a screwdriver, pliers, and wrench.

1.Carefully remove the equipment from the carton and check for any evidence of damage due to rough handling or shipping. If any of the equipment is damaged, immediately notify the organization where the equipment was purchased.

2.Position a tee-nut on the boss underneath the skid base. Screw a bolt with washer into the tee-nut from the top of the base. Continue screwing the bolt into the tee-nut until the tee-nut is flush with the boss. Unscrew the bolt. Repeat procedure for the remaining bosses.

3.This filter should be mounted on a level concrete slab, preferably concrete poured in a form or on a platform constructed of concrete block or brick.

4. Depending upon how your skimmer is positioned in

DetailC

 

relationship to the return fitting, see Diagram 3, either

Detail D

right or left of the skimmer, position the mounting base

 

accordingly; see Diagram 3. Position the filter tank on

 

the mounting base so the filter inlet port is oriented

 

toward the pump similar to Diagram 2. Secure the filter

 

to the mounting base using two bolt fasteners. Place

DetailB

the pump on the mounting base; see Diagram 2.

 

Loosely attach the pump connector, see Detail A, to the

inlet

pump and filter. This will align the pump to the correct

 

set of mounting holes. Secure the pump to the base

 

using two bolt fasteners. Tighten the union fittings on

 

the plumbing connector by hand until tight. If water

 

leakage occurs at these connections, adjust

Detail A

connections with a wrench making sure not to exceed 1/

 

4 of a turn.

Diagram2.

P/N 99101100

4

REV. F 5-1-01

Page 4
Image 4
System Works 99101100 manual Section Iv. Installation, inlet, Detail A