Wiring
HV1600
The HV1600 is connected to power through the line cord and must be plugged into a constant, grounded power source. When connected to power, it will be fully functional with the hand held remote control unit. When any of the buttons on the remote control are pushed, the red indicator light should momentarily flash.
Optional Controls:
Hardwiring the unit to wall switches using the BLUE and YELLOW wires will provide additional, manual control. The BLUE wire will provide on/off control and the YELLOW wire will provide high or low speed control. Using a switch in the ON position will override the remote control function.
Use only SPST (single pole, single throw) switches.
Drawing is not to scale

Wiring

Important - Because of the motorized doors, wiring the HV is different than a normal ON/OFF fan. Please follow the instructions carefully. Be sure to turn off power before wiring the HV Whole House Fan It is recommended that the wiring of the HV be done by a licensed electrician.

The HV requires a constant source of power. Because the doors are motorized, they need power to open and power to close. The fan operation is controlled internally.

HV1000

There are three wires in the electrical box: WHITE, RED, and BLACK.

• Connect the WHITE wire to Line Neutral

• Connect the RED wire to Line Hot

• Connect the BLACK wire to a Switched Hot Feed

When 115 VAC Hot is applied to it, the doors will open. When 115 VAC Hot is removed, the doors will close.

• Connect the ground wire to the screw in the electrical box

Drawing is not to scale

The HV whole house cooling fans are not for use with solid state speed controls

HV1000Care A Remote Control Kit for the HV1000 is available and may be purchased separately. Installation is quick and easy and it may be installed at any time.

Care

All the motors in the HV are permanently sealed and do not require oiling. To keep dirt, dust and debris from the fans we recommend that you periodically remove the grille from within the living space and dust the fan blades. Please remember to make sure that the fan is OFF before dusting the fan blades.

Specifications

Voltage ……………………………. 115VAC 60 Hz

Power

HV1000…………..…....... 112 Watts

HV1600…………..…....... 276 Watts

Airflow @ .03” (System)

HV1000 …………...……. 1000 CFM

HV1600 High……..……. 1600 CFM

HV1600 Low …………… 900 CFM

R-Value

 

 

HV1000 & HV1600-GR

R-22

HV1000-DB & HV1600-GDR

R-38

Weight

 

 

HV1000………………….

17

Lbs.

HV1600…………………

21

Lbs.

Rough Opening……………………

14

½” x 22 ½”

Grille Dimensions………………….

15

¾” x 25 ¾”

Grille Color ………………………... White