Technical Description of TANDBERG Gateway with software version G2
4.3 RS232 Interface/Application Programmable Interface (API)
Data Standards | Data | TANDBERG Dynamic Data Channel (DDC) |
| Modem | Standard modem commands |
Data Interfaces | 1 x Data port, |
The RS232 port on the TANDBERG Gateway is implemented as Digital Circuit Terminating Equipment (DCE).
The connectors used are female
Signal Name | Direction | Pin number |
Carrier detect, CD | From DCE | 1 |
Receive data, RXD | From DCE | 2 |
Transmit data, TXD | To DCE | 3 |
Data terminal ready, DTR | From DCE | 4 |
Signal ground, GND |
| 5 |
Data set ready, DSR | From DCE | 6 |
Ready to send, RTS | To DCE | 7 |
Clear to send, CTS | From DCE | 8 |
Ring indicator, RI | From DCE | 9 |
Note: The API commands may also be accessed via Telnet, through the TANDBERG Gateway’s Ethernet connection.
4.3.1API commands
Please refer to the document ‘TANDBERG Gateway API’ (D13202) for details. The RS232 port is used for local software upgrades, local control and diagnostics.
Also, refer to ‘TANDBERG SNMP’ (D12190) for SNMP implementation.
D13192 Rev. 02 | 21 |