Technical Description of TANDBERG Gateway with software version G2
Pinout of PRI E1/T1 Interface:4
PRI Pinout
1TIP RX
2RING RX
4RING TX
5TIP TX
NOTE: TANDBERG recommends always using category 5 cabling.
PRI T1 (US only):
Network Service Facility (NSF) can be configured as blank/no value (i.e. NSF not used – default) or any value between 0 and 31, to describe the service facility on the PRI/T1 line.
AT&T |
|
Service code (ref.1) | Service |
0 | Disable |
1 | SDN (Including GSDN) |
2 | Toll Free Megacom (800) |
3 | Megacom |
6 | ACCUNET Switched Digital Service (incl. Switched Digital International) |
7 | Long Distance Service (incl. AT&T World Connect) |
8 | International Toll Free Service (1800) |
16 | AT&T MultiQuest |
23 | Call Redirection Service |
Sprint |
|
Service code (ref.2) | Service |
0 | Reserved |
1 | Private |
2 | Inwatts |
3 | Outwatts |
4 | FX |
5 | TieTrunk |
MCI |
|
Service code (ref.2) | Service |
1 | VNET/Vision |
2 | 800 |
3 | PRISM1, PRISMII, WATS |
4 | 900 |
5 | DAL |
Ref. 1: AT&T TR 414859 Specification, June 1999, page 76
Ref. 2: Ascend Multiband
4 The cable of use should be a straight through configuration.
D13192 Rev. 02 | 8 |