Tanita TL-150MA Specifications, Model, Accuracy at first calibration, Maximum tare effect

Models: TL-150MA

1 37
Download 37 pages 45.37 Kb
Page 7
Image 7

TL-150MA/6カ国/01.12 01.12.27 1:23 PM ページ 12

Specifications

GB

 

 

Model

TL-150MA

 

 

 

AC adapter Centre minus MODEL A30930G CLASS 2

 

 

 

Input Voltage : 230VAC 50Hz 65mA

 

Power Source

Output Voltage : 9VDC±0.45VDC

 

Rated Current : 300mA

 

 

 

 

 

 

No Load Input Voltage : 12VDC±0.6VDC

 

 

 

Alkali battery (LR14) x 6, (Not included)

 

 

 

 

 

Power Consumption

0.2W max.

Measurement System

Electrical resistance method

 

Maximum Capacity

6kg , 15kg

 

 

 

6kg : 2g

Minimum Graduation

15kg : 5g

 

 

 

*Multiple range instrument

 

 

 

 

Accuracy at first calibration

6kg : ±4g

15kg : ±10g

 

 

 

 

 

 

 

 

Weighing Range

40g - 6kg

 

100g - 15kg

 

 

 

 

 

 

 

 

Maximum tare effect

4kg

 

 

Display

LCD (Liquid crystal) (Height of numerals 14mm)

Temperature Range of Usage

+5˚C / +35˚C

 

Relative Humidity

30 - 80% (without condensation)

Size

 

Baby basket

564 x 276 x 105 (mm)

 

Assembled Dimensions

564 x 330 x 190 (mm)

 

 

 

Battery Life

approximately 300 hours of continuous use

The product meets all the requirements under the three standards below:

Safety Standard

: EN60601-1:1990, AM No.1:1993, AM No.2:1995

 

IEC60601-1:1988, AM No.1:1991, AM No.2:1995

EMC Standard

: EN-60601-1-2:1993

 

IEC60601-1-2:1993

Medical Device Directory Standard

:93/42/EEC:1993

<Corporation Responsible in the EU Region>

The Barn, Philpots Close, Yiewsley,

Middlesex,

UB7 7RY, United Kingdom

Tel : 01895-438577 Fax : 01895-438511

http://www.tanita.co.uk

14-2,1-chome,Maeno-cho,Itabashi-ku Tokyo,Japan

Tel:(03)3968-2123 / (03)3968-7048 Fax:(03)3967-3766

2625 South Clearbrook Drive

Unit 301-303 3/F Wing On Plaza,

Dresdener Strasse 25

Villa Labrouste

Arlington Heights, Illinois 60005 U.S.A.

62 Mody Road, Tsimshatsui East,

D-71065 Sindelfingen,

68 Boulevard Bourdon,

Toll Free : (800) 826-4828

Kowloon, Hong Kong

Germany

92200 Neuilly-Sur-Seine,

Tel : 847-640-9241

Tel : +852-2838-7111

Tel : 07031-61896

France

Fax : 847-640-9261

Fax : +852-2838-8667

Fax : 07031-618971

Tel : 01-55-24-99-99

http : //www.tanita.com

 

http://www.tanita.de

Fax : 01-55-24-98-68

 

 

 

http://www.tanita.fr

D

ELEKTRONISCHE WAAGE

FÜR KLEINKINDER UND SÄUGLINGE

TL-150MA

BEDIENUNGSANLEITUNG

mBitte lesen Sie diese Bedienungsanleitung sorgfältig durch und bewahren Sie sie griffbereit auf.

TL1507001(1)

Page 7
Image 7
Tanita TL-150MA instruction manual Specifications, Model, Accuracy at first calibration, Maximum tare effect