Tannoy V12HP user manual Passive System Parameters optional

Models: V12HP

1 22
Download 22 pages 46.13 Kb
Page 18
Image 18

13.2 Passive System Parameters (optional)

With the vast array of digital loudspeaker management systems available it is inevitable that the user may opt to use a controller other than the TX2 & TDX2 as part of a large scale integrated system. In passive mode the V12HP has been designed to need no external equalisation to overcome system limitations. If the V12HP is to be used alone with additional bass enhancement required and have the frequency response limits tighter than +/- 3dB as stated in section 11, then apply the parameters in the table below for optimised performance:-

Parameter

Unit/Name

 

 

 

 

Gain

(dB)

User definable

Delay

(ms)

User definable

Polarity

 

Positive

 

 

 

HPF Ä

Freq (Hz)

42.5

 

Slope (dB/oct)

24

 

Filter Shape

Butterworth

 

 

 

LPF

Freq (Hz)

Thru

 

Slope (dB/oct)

NA

 

Filter Shape

NA

 

 

 

 

 

 

PEQ 1 Ä

Freq (Hz)

62.5

 

Level (dB)

+7

 

Type

Parametric

 

Q / Bandwidth

2.5 / 0.3969

 

 

 

PEQ 2

Freq (Hz)

680

 

Level (dB)

-3.5

 

Type

Parametric

 

Q / Bandwidth

1 / 1.000

 

 

 

PEQ 3

Freq (Hz)

1410

 

Level (dB)

-1

 

Type

Parametric

 

Q / Bandwidth

4 / 0.2500

 

 

 

PEQ 4

Freq (Hz)

7130

 

Level (dB)

-2

 

Type

Parametric

 

Q / Bandwidth

2 / 0.500

 

 

 

PEQ 5

Freq (Hz)

NA

 

Level (dB)

NA

 

Type

NA

 

Q / Bandwidth

NA

 

 

 

ÄNote : When using the V12HP with subs, set HPF @ 80 – 110Hz (24dB/oct LR) and omit PEQ1.

PEQ 1 may also be omitted when using the V12HP as a floor monitor.

Page 18