13.3 Biamp System Parameters
Parameter | Unit/Name | Low Section | High Section |
|
|
|
|
Gain | (dB) | 0 | |
Delay | (ms) | 0.167 | 0 |
Polarity |
| Positive | Positive |
|
|
|
|
HPF Ä | Freq (Hz) | 42.5 | 1680 |
| Slope (dB/oct) | 24 | 24 |
| Filter Shape | Butterworth | Linkwitz Riley |
|
|
|
|
LPF | Freq (Hz) | 1470 | Thru |
| Slope (dB/oct) | 24 | NA |
| Filter Shape | Linkwitz Riley | NA |
|
|
|
|
PEQ 1 Ä | Freq (Hz) | 62.5 | 2720 |
| Level (dB) | +7 | |
| Type | Parametric | Parametric |
| Q / Bandwidth | 2.0 / 0.5000 | 2.1 / 0.4719 |
|
|
|
|
PEQ 2 | Freq (Hz) | 454 | 10700 |
| Level (dB) | +5 | |
| Type | Parametric | Parametric |
| Q / Bandwidth | 1.7 / 0.5946 | 1.9 / 0.5297 |
|
|
|
|
PEQ 3 | Freq (Hz) | 642 | 15100 |
| Level (dB) | +3 | |
| Type | Parametric | 2.4 / 0.4204 |
| Q / Bandwidth | 4.0 / 0.2500 | NA |
|
|
|
|
PEQ 4 | Freq (Hz) | 1010 | NA |
| Level (dB) | +6 | NA |
| Type | Parametric | NA |
| Q / Bandwidth | 4.0 / 0.2500 | NA |
|
|
|
|
PEQ 5 | Freq (Hz) | NA | NA |
| Level (dB) | NA | NA |
| Type | NA | NA |
| Q / Bandwidth | NA | NA |
|
|
|
|
ÄNote : When using the V12HP with subs, set HPF on LF section @ 80 – 110Hz (24dB/oct LR) and omit PEQ1 (on LF only)
PEQ 1 (on LF only) may also be omitted when using the V12HP as a floor monitor.