13.3 Biamp System Parameters

Parameter

Unit/Name

Low Section

High Section

 

 

 

 

Gain

(dB)

0

-1.0

Delay

(ms)

0.167

0

Polarity

 

Positive

Positive

 

 

 

 

HPF Ä

Freq (Hz)

42.5

1680

 

Slope (dB/oct)

24

24

 

Filter Shape

Butterworth

Linkwitz Riley

 

 

 

 

LPF

Freq (Hz)

1470

Thru

 

Slope (dB/oct)

24

NA

 

Filter Shape

Linkwitz Riley

NA

 

 

 

 

PEQ 1 Ä

Freq (Hz)

62.5

2720

 

Level (dB)

+7

-4

 

Type

Parametric

Parametric

 

Q / Bandwidth

2.0 / 0.5000

2.1 / 0.4719

 

 

 

 

PEQ 2

Freq (Hz)

454

10700

 

Level (dB)

-3

+5

 

Type

Parametric

Parametric

 

Q / Bandwidth

1.7 / 0.5946

1.9 / 0.5297

 

 

 

 

PEQ 3

Freq (Hz)

642

15100

 

Level (dB)

-2

+3

 

Type

Parametric

2.4 / 0.4204

 

Q / Bandwidth

4.0 / 0.2500

NA

 

 

 

 

PEQ 4

Freq (Hz)

1010

NA

 

Level (dB)

+6

NA

 

Type

Parametric

NA

 

Q / Bandwidth

4.0 / 0.2500

NA

 

 

 

 

PEQ 5

Freq (Hz)

NA

NA

 

Level (dB)

NA

NA

 

Type

NA

NA

 

Q / Bandwidth

NA

NA

 

 

 

 

ÄNote : When using the V12HP with subs, set HPF on LF section @ 80 – 110Hz (24dB/oct LR) and omit PEQ1 (on LF only)

PEQ 1 (on LF only) may also be omitted when using the V12HP as a floor monitor.

Page 19
Image 19
Tannoy V12HP user manual 167